Cargando…

Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam

TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION...

Descripción completa

Detalles Bibliográficos
Autores principales: Arduini, Gianluigi, Colchester, R J, Ferioli, G, Giovanazzi, M, Gras, J J, Hanke, K, Hopkins, D J, Jung, R, Manglunki, Django, Martini, M
Lenguaje:eng
Publicado: 1999
Materias:
Acceso en línea:http://cds.cern.ch/record/702533
_version_ 1780902310356975616
author Arduini, Gianluigi
Colchester, R J
Ferioli, G
Giovanazzi, M
Gras, J J
Hanke, K
Hopkins, D J
Jung, R
Manglunki, Django
Martini, M
author_facet Arduini, Gianluigi
Colchester, R J
Ferioli, G
Giovanazzi, M
Gras, J J
Hanke, K
Hopkins, D J
Jung, R
Manglunki, Django
Martini, M
author_sort Arduini, Gianluigi
collection CERN
description TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.
id cern-702533
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1999
record_format invenio
spelling cern-7025332023-05-11T12:03:28Zhttp://cds.cern.ch/record/702533engArduini, GianluigiColchester, R JFerioli, GGiovanazzi, MGras, J JHanke, KHopkins, D JJung, RManglunki, DjangoMartini, MMismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beamAccelerators and Storage RingsTRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.SL-Note-99-032-MDoai:cds.cern.ch:7025331999-06-10
spellingShingle Accelerators and Storage Rings
Arduini, Gianluigi
Colchester, R J
Ferioli, G
Giovanazzi, M
Gras, J J
Hanke, K
Hopkins, D J
Jung, R
Manglunki, Django
Martini, M
Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title_full Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title_fullStr Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title_full_unstemmed Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title_short Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
title_sort mismatch measurement and correction tools for the ps-sps transfer of the 26gev/c lhc beam
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702533
work_keys_str_mv AT arduinigianluigi mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT colchesterrj mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT feriolig mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT giovanazzim mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT grasjj mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT hankek mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT hopkinsdj mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT jungr mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT manglunkidjango mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam
AT martinim mismatchmeasurementandcorrectiontoolsforthepsspstransferofthe26gevclhcbeam