Cargando…

Orbit Steering and Central Frequency for LEP2 Energy Calibration

"The central frequency is an important parameter of the LEP beam energy model. It is a direct measurementof the LEP circumference and is used to evaluate the contribution of the quadrupoles to field integral relevant forthe LEP beam ebergy. Its evolution over a run is tracked using direct frequ...

Descripción completa

Detalles Bibliográficos
Autor principal: Wenninger, J
Lenguaje:eng
Publicado: 2000
Materias:
Acceso en línea:http://cds.cern.ch/record/702574
_version_ 1780902318213955584
author Wenninger, J
author_facet Wenninger, J
author_sort Wenninger, J
collection CERN
description "The central frequency is an important parameter of the LEP beam energy model. It is a direct measurementof the LEP circumference and is used to evaluate the contribution of the quadrupoles to field integral relevant forthe LEP beam ebergy. Its evolution over a run is tracked using direct frequency measurementscombined with radial beam position measurements in the LEP arcs.The influence of orbit corrections on the central frequency measurement techniques was evaluatedand a model allowing to correct for changes of corrector settings was developped.The central frequency data for the LEP2 runs between 1996 and 1999 was re-analysed to includecorrections due to the closed orbit steering."
id cern-702574
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2000
record_format invenio
spelling cern-7025742023-05-11T12:03:29Zhttp://cds.cern.ch/record/702574engWenninger, JOrbit Steering and Central Frequency for LEP2 Energy CalibrationAccelerators and Storage Rings"The central frequency is an important parameter of the LEP beam energy model. It is a direct measurementof the LEP circumference and is used to evaluate the contribution of the quadrupoles to field integral relevant forthe LEP beam ebergy. Its evolution over a run is tracked using direct frequency measurementscombined with radial beam position measurements in the LEP arcs.The influence of orbit corrections on the central frequency measurement techniques was evaluatedand a model allowing to correct for changes of corrector settings was developped.The central frequency data for the LEP2 runs between 1996 and 1999 was re-analysed to includecorrections due to the closed orbit steering."SL-Note-2000-009-OPoai:cds.cern.ch:7025742000-02-03
spellingShingle Accelerators and Storage Rings
Wenninger, J
Orbit Steering and Central Frequency for LEP2 Energy Calibration
title Orbit Steering and Central Frequency for LEP2 Energy Calibration
title_full Orbit Steering and Central Frequency for LEP2 Energy Calibration
title_fullStr Orbit Steering and Central Frequency for LEP2 Energy Calibration
title_full_unstemmed Orbit Steering and Central Frequency for LEP2 Energy Calibration
title_short Orbit Steering and Central Frequency for LEP2 Energy Calibration
title_sort orbit steering and central frequency for lep2 energy calibration
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702574
work_keys_str_mv AT wenningerj orbitsteeringandcentralfrequencyforlep2energycalibration