Measurements with the 132/90 optics in LEP
0.5 Gev could be gained on the LEP energy by using a 132/90 optics instead of the current 102/90 optics thanks to the reduction of the momentum compaction factor. The drawback of the 132/90 optics is the large negative anharmonicity.The working point has been set far from the systematic 3rd resonanc...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/702584 |
_version_ | 1780902320198909952 |
---|---|
author | Verdier, A Schmidt, F Leunissen, L H A |
author_facet | Verdier, A Schmidt, F Leunissen, L H A |
author_sort | Verdier, A |
collection | CERN |
description | 0.5 Gev could be gained on the LEP energy by using a 132/90 optics instead of the current 102/90 optics thanks to the reduction of the momentum compaction factor. The drawback of the 132/90 optics is the large negative anharmonicity.The working point has been set far from the systematic 3rd resonance.The aim of the experiment was to try to inject a maximum current and to measure non-linear optics parameters at injection energy. |
id | cern-702584 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-7025842023-05-11T12:03:30Zhttp://cds.cern.ch/record/702584engVerdier, ASchmidt, FLeunissen, L H AMeasurements with the 132/90 optics in LEPAccelerators and Storage Rings0.5 Gev could be gained on the LEP energy by using a 132/90 optics instead of the current 102/90 optics thanks to the reduction of the momentum compaction factor. The drawback of the 132/90 optics is the large negative anharmonicity.The working point has been set far from the systematic 3rd resonance.The aim of the experiment was to try to inject a maximum current and to measure non-linear optics parameters at injection energy.SL-Note-2000-018-MDoai:cds.cern.ch:7025842000-02-25 |
spellingShingle | Accelerators and Storage Rings Verdier, A Schmidt, F Leunissen, L H A Measurements with the 132/90 optics in LEP |
title | Measurements with the 132/90 optics in LEP |
title_full | Measurements with the 132/90 optics in LEP |
title_fullStr | Measurements with the 132/90 optics in LEP |
title_full_unstemmed | Measurements with the 132/90 optics in LEP |
title_short | Measurements with the 132/90 optics in LEP |
title_sort | measurements with the 132/90 optics in lep |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/702584 |
work_keys_str_mv | AT verdiera measurementswiththe13290opticsinlep AT schmidtf measurementswiththe13290opticsinlep AT leunissenlha measurementswiththe13290opticsinlep |