H8 Electron beam quality improvement during 2001

Since 1999 the ATLAS calorimeter groups who are the main users of the H8 beam line were observing a deterioration of the electron beam quality of the beam. Several studies, within the limited time available due to the tight SPS schedule, were performed before 2001 but without success. Following a sy...

Descripción completa

Detalles Bibliográficos
Autores principales: Efthymiopoulos, I, Elsener, K
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/702699
_version_ 1780902340489904128
author Efthymiopoulos, I
Elsener, K
author_facet Efthymiopoulos, I
Elsener, K
author_sort Efthymiopoulos, I
collection CERN
description Since 1999 the ATLAS calorimeter groups who are the main users of the H8 beam line were observing a deterioration of the electron beam quality of the beam. Several studies, within the limited time available due to the tight SPS schedule, were performed before 2001 but without success. Following a systematic study of the problem in 2001, and in collaboration with the ATLAS colleagues, the origin of the problem was found and the beam quality was restored to the level before 1999. Details of the studies performed and the final results on the electron beam quality are summarized here.
id cern-702699
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-7026992023-08-16T09:16:40Zhttp://cds.cern.ch/record/702699engEfthymiopoulos, IElsener, KH8 Electron beam quality improvement during 2001Accelerators and Storage RingsSince 1999 the ATLAS calorimeter groups who are the main users of the H8 beam line were observing a deterioration of the electron beam quality of the beam. Several studies, within the limited time available due to the tight SPS schedule, were performed before 2001 but without success. Following a systematic study of the problem in 2001, and in collaboration with the ATLAS colleagues, the origin of the problem was found and the beam quality was restored to the level before 1999. Details of the studies performed and the final results on the electron beam quality are summarized here.SL-Note-2002-018-EAoai:cds.cern.ch:7026992002-05-31
spellingShingle Accelerators and Storage Rings
Efthymiopoulos, I
Elsener, K
H8 Electron beam quality improvement during 2001
title H8 Electron beam quality improvement during 2001
title_full H8 Electron beam quality improvement during 2001
title_fullStr H8 Electron beam quality improvement during 2001
title_full_unstemmed H8 Electron beam quality improvement during 2001
title_short H8 Electron beam quality improvement during 2001
title_sort h8 electron beam quality improvement during 2001
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702699
work_keys_str_mv AT efthymiopoulosi h8electronbeamqualityimprovementduring2001
AT elsenerk h8electronbeamqualityimprovementduring2001