Cargando…
CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ?
The CNGS design has been approved with two muon detector stations, separated by 67 metres of rock. During the recent discussions on cost reduction, it has been suggested that a possible saving would be to postpone equipping the second muon detector station. The importance of the second array of muon...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/702721 |
_version_ | 1780902344600322048 |
---|---|
author | Ball, A E Elsener, K Falaleev, V P Ferrari, A Grant, A Guglielmi, A M Meddahi, M Pietropaolo, F Sala, P |
author_facet | Ball, A E Elsener, K Falaleev, V P Ferrari, A Grant, A Guglielmi, A M Meddahi, M Pietropaolo, F Sala, P |
author_sort | Ball, A E |
collection | CERN |
description | The CNGS design has been approved with two muon detector stations, separated by 67 metres of rock. During the recent discussions on cost reduction, it has been suggested that a possible saving would be to postpone equipping the second muon detector station. The importance of the second array of muon detectors, in particular at the start-up of CNGS, is being described in this note. It is argued that both muon detector stations must be operational from the beginning of CNGS operation. |
id | cern-702721 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-7027212023-05-11T12:03:36Zhttp://cds.cern.ch/record/702721engBall, A EElsener, KFalaleev, V PFerrari, AGrant, AGuglielmi, A MMeddahi, MPietropaolo, FSala, PCNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ?Accelerators and Storage RingsThe CNGS design has been approved with two muon detector stations, separated by 67 metres of rock. During the recent discussions on cost reduction, it has been suggested that a possible saving would be to postpone equipping the second muon detector station. The importance of the second array of muon detectors, in particular at the start-up of CNGS, is being described in this note. It is argued that both muon detector stations must be operational from the beginning of CNGS operation.SL-Note-2002-040-EAoai:cds.cern.ch:7027212002-12-05 |
spellingShingle | Accelerators and Storage Rings Ball, A E Elsener, K Falaleev, V P Ferrari, A Grant, A Guglielmi, A M Meddahi, M Pietropaolo, F Sala, P CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title | CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title_full | CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title_fullStr | CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title_full_unstemmed | CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title_short | CNGS muon monitoring: Why do we need both muon detector stations at the start-up of the CNGS neutrino beam ? |
title_sort | cngs muon monitoring: why do we need both muon detector stations at the start-up of the cngs neutrino beam ? |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/702721 |
work_keys_str_mv | AT ballae cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT elsenerk cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT falaleevvp cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT ferraria cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT granta cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT guglielmiam cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT meddahim cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT pietropaolof cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam AT salap cngsmuonmonitoringwhydoweneedbothmuondetectorstationsatthestartupofthecngsneutrinobeam |