Cargando…

Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002

In the end-of-the-store study on November 17, 2002, we excited individual pbar bunches using the Tevatron Electron Lens (TEL) and detected the associated signals in the proton and pbar vertical Schottky spectra, as well as their response to pbar and proton tune changes The tune for the p-bar bunch A...

Descripción completa

Detalles Bibliográficos
Autores principales: Zimmermann, Frank, Shiltsev, V D, Zhang, X L
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/702737
_version_ 1780902347216519168
author Zimmermann, Frank
Shiltsev, V D
Zhang, X L
author_facet Zimmermann, Frank
Shiltsev, V D
Zhang, X L
author_sort Zimmermann, Frank
collection CERN
description In the end-of-the-store study on November 17, 2002, we excited individual pbar bunches using the Tevatron Electron Lens (TEL) and detected the associated signals in the proton and pbar vertical Schottky spectra, as well as their response to pbar and proton tune changes The tune for the p-bar bunch A24 could thus be inferred. Subsequently, the antiprotons were slowly scraped to nearly zero intensity, in an attempt to compare the p-bar emittances obtained by the flying wires and by the synchrotron light monitor with those derived from the remaining beam intensity measured as a function of collimator position.
id cern-702737
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-7027372023-02-17T10:08:14Zhttp://cds.cern.ch/record/702737engZimmermann, FrankShiltsev, V DZhang, X LTevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002Accelerators and Storage RingsIn the end-of-the-store study on November 17, 2002, we excited individual pbar bunches using the Tevatron Electron Lens (TEL) and detected the associated signals in the proton and pbar vertical Schottky spectra, as well as their response to pbar and proton tune changes The tune for the p-bar bunch A24 could thus be inferred. Subsequently, the antiprotons were slowly scraped to nearly zero intensity, in an attempt to compare the p-bar emittances obtained by the flying wires and by the synchrotron light monitor with those derived from the remaining beam intensity measured as a function of collimator position.AB-Note-2003-007-MDoai:cds.cern.ch:7027372003-01-23
spellingShingle Accelerators and Storage Rings
Zimmermann, Frank
Shiltsev, V D
Zhang, X L
Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title_full Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title_fullStr Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title_full_unstemmed Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title_short Tevatron Study Report: pbbar Tunes and pbbar Removal from 17 Nov 2002
title_sort tevatron study report: pbbar tunes and pbbar removal from 17 nov 2002
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/702737
work_keys_str_mv AT zimmermannfrank tevatronstudyreportpbbartunesandpbbarremovalfrom17nov2002
AT shiltsevvd tevatronstudyreportpbbartunesandpbbarremovalfrom17nov2002
AT zhangxl tevatronstudyreportpbbartunesandpbbarremovalfrom17nov2002