Laser scan with upstream crystal #1
A laser scan was performed with the new U-shaped crystal G5, which has a known miscut of +1 mrad and is installed at the upstream position #1 in the TEC. The aim was to cross-check the angular sensitivity of the stepping motor of the goniometer, which theoretically should be 1.98 µrad/step.