Cargando…
Crystal extraction: Alignment of crystal with respect to the beam
The program CRYSTAL.BAS allows to calculate the exact alignment of the crystal with respect to thebeam. It is written in QBasic and installed on server USRV_865 connected to the PC network. This note describes how to access and to run this program from any PC which is connected to the network NICE....
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2000
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/703273 |
_version_ | 1780902377011806208 |
---|---|
author | Gyr, Marcel |
author_facet | Gyr, Marcel |
author_sort | Gyr, Marcel |
collection | CERN |
description | The program CRYSTAL.BAS allows to calculate the exact alignment of the crystal with respect to thebeam. It is written in QBasic and installed on server USRV_865 connected to the PC network. This note describes how to access and to run this program from any PC which is connected to the network NICE. The angle of the two crystals actually installed has been scanned over a relatively wide range and at different positions with respect to the ideal closed orbit, thereafter referred to as beam center line. The signal (Volt) produced by the position sensitive detectors (PSD) intercepting the reflected laser beams used to monitor the crystal alignment, is plotted in the attached figures. |
id | cern-703273 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2000 |
record_format | invenio |
spelling | cern-7032732023-05-11T12:03:38Zhttp://cds.cern.ch/record/703273engGyr, MarcelCrystal extraction: Alignment of crystal with respect to the beamAccelerators and Storage RingsThe program CRYSTAL.BAS allows to calculate the exact alignment of the crystal with respect to thebeam. It is written in QBasic and installed on server USRV_865 connected to the PC network. This note describes how to access and to run this program from any PC which is connected to the network NICE. The angle of the two crystals actually installed has been scanned over a relatively wide range and at different positions with respect to the ideal closed orbit, thereafter referred to as beam center line. The signal (Volt) produced by the position sensitive detectors (PSD) intercepting the reflected laser beams used to monitor the crystal alignment, is plotted in the attached figures.SL-Note-92-55-BToai:cds.cern.ch:7032732000-03-01 |
spellingShingle | Accelerators and Storage Rings Gyr, Marcel Crystal extraction: Alignment of crystal with respect to the beam |
title | Crystal extraction: Alignment of crystal with respect to the beam |
title_full | Crystal extraction: Alignment of crystal with respect to the beam |
title_fullStr | Crystal extraction: Alignment of crystal with respect to the beam |
title_full_unstemmed | Crystal extraction: Alignment of crystal with respect to the beam |
title_short | Crystal extraction: Alignment of crystal with respect to the beam |
title_sort | crystal extraction: alignment of crystal with respect to the beam |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/703273 |
work_keys_str_mv | AT gyrmarcel crystalextractionalignmentofcrystalwithrespecttothebeam |