Cargando…
Performance of Multianode Photo Multiplier Tubes at Low Gain
A study of the signal response of Multianode Photo Multiplier Tubes (MaPMT) is presented for gains spanning the range of at least $3cdot10^{4}<G<5cdot10^{6},e^{-}$. The feasibility of running the MaPMT at gains of around $ m 30000~e^{-}$ is investigated to evaluate the direct readout of MaPMT...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/704644 |
_version_ | 1780902432377667584 |
---|---|
author | Eisenhardt, S Muheim, F |
author_facet | Eisenhardt, S Muheim, F |
author_sort | Eisenhardt, S |
collection | CERN |
description | A study of the signal response of Multianode Photo Multiplier Tubes (MaPMT) is presented for gains spanning the range of at least $3cdot10^{4}<G<5cdot10^{6},e^{-}$. The feasibility of running the MaPMT at gains of around $ m 30000~e^{-}$ is investigated to evaluate the direct readout of MaPMT with front-end chips that have been developed for silicon detector or micro strip gas chambers. In order to characterise the shape of the signal spectra and to specify the loss of signal below a threshold cut an improved fitting algorithm is used. |
id | cern-704644 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7046442019-09-30T06:29:59Zhttp://cds.cern.ch/record/704644engEisenhardt, SMuheim, FPerformance of Multianode Photo Multiplier Tubes at Low GainDetectors and Experimental TechniquesA study of the signal response of Multianode Photo Multiplier Tubes (MaPMT) is presented for gains spanning the range of at least $3cdot10^{4}<G<5cdot10^{6},e^{-}$. The feasibility of running the MaPMT at gains of around $ m 30000~e^{-}$ is investigated to evaluate the direct readout of MaPMT with front-end chips that have been developed for silicon detector or micro strip gas chambers. In order to characterise the shape of the signal spectra and to specify the loss of signal below a threshold cut an improved fitting algorithm is used.LHCb-2003-043oai:cds.cern.ch:7046442004-01-09 |
spellingShingle | Detectors and Experimental Techniques Eisenhardt, S Muheim, F Performance of Multianode Photo Multiplier Tubes at Low Gain |
title | Performance of Multianode Photo Multiplier Tubes at Low Gain |
title_full | Performance of Multianode Photo Multiplier Tubes at Low Gain |
title_fullStr | Performance of Multianode Photo Multiplier Tubes at Low Gain |
title_full_unstemmed | Performance of Multianode Photo Multiplier Tubes at Low Gain |
title_short | Performance of Multianode Photo Multiplier Tubes at Low Gain |
title_sort | performance of multianode photo multiplier tubes at low gain |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/704644 |
work_keys_str_mv | AT eisenhardts performanceofmultianodephotomultipliertubesatlowgain AT muheimf performanceofmultianodephotomultipliertubesatlowgain |