Cargando…
Loop Gain and Impedance Considerations for the LHC RF Cavities
The LHC superconducting cavities will be operated with variable power coupling which changes the loop gain of the fast RF feedback system. Therefore we have established a mathematical formula for the absolute stability limit of such a feedback system with linear delay and cross-checked it numericall...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/708746 |
_version_ | 1780902504671739904 |
---|---|
author | Tückmantel, Joachim |
author_facet | Tückmantel, Joachim |
author_sort | Tückmantel, Joachim |
collection | CERN |
description | The LHC superconducting cavities will be operated with variable power coupling which changes the loop gain of the fast RF feedback system. Therefore we have established a mathematical formula for the absolute stability limit of such a feedback system with linear delay and cross-checked it numerically with a program that assumes only very basic physical relations. Results show that to keep the beam impedance constant we have to ramp the gain G of the amplifier in the loop. Even with this gain change the loop will remain stable. |
id | cern-708746 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7087462019-09-30T06:29:59Zhttp://cds.cern.ch/record/708746engTückmantel, JoachimLoop Gain and Impedance Considerations for the LHC RF CavitiesAccelerators and Storage RingsThe LHC superconducting cavities will be operated with variable power coupling which changes the loop gain of the fast RF feedback system. Therefore we have established a mathematical formula for the absolute stability limit of such a feedback system with linear delay and cross-checked it numerically with a program that assumes only very basic physical relations. Results show that to keep the beam impedance constant we have to ramp the gain G of the amplifier in the loop. Even with this gain change the loop will remain stable.AB-Note-2004-010-RFCERN-AB-Note-2004-010-RFoai:cds.cern.ch:7087462004-02-12 |
spellingShingle | Accelerators and Storage Rings Tückmantel, Joachim Loop Gain and Impedance Considerations for the LHC RF Cavities |
title | Loop Gain and Impedance Considerations for the LHC RF Cavities |
title_full | Loop Gain and Impedance Considerations for the LHC RF Cavities |
title_fullStr | Loop Gain and Impedance Considerations for the LHC RF Cavities |
title_full_unstemmed | Loop Gain and Impedance Considerations for the LHC RF Cavities |
title_short | Loop Gain and Impedance Considerations for the LHC RF Cavities |
title_sort | loop gain and impedance considerations for the lhc rf cavities |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/708746 |
work_keys_str_mv | AT tuckmanteljoachim loopgainandimpedanceconsiderationsforthelhcrfcavities |