Cargando…
Statistical Effects in Beam Profile Monitors
The development of segmented beam profile monitors, like wire grids, segmented photo tubes etc., require the optimisation of several detector parameters like; the size of the active area, the number of channels and the integration time. The influence of some of these parameters can be calculated by...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/710825 |
_version_ | 1780902647453188096 |
---|---|
author | Bravin, Enrico |
author_facet | Bravin, Enrico |
author_sort | Bravin, Enrico |
collection | CERN |
description | The development of segmented beam profile monitors, like wire grids, segmented photo tubes etc., require the optimisation of several detector parameters like; the size of the active area, the number of channels and the integration time. The influence of some of these parameters can be calculated by means of montecarlo simulations. In this paper the influence of these parameters on the measurement error is investigated by mean of numerical simulations. |
id | cern-710825 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7108252019-09-30T06:29:59Zhttp://cds.cern.ch/record/710825engBravin, EnricoStatistical Effects in Beam Profile MonitorsAccelerators and Storage RingsThe development of segmented beam profile monitors, like wire grids, segmented photo tubes etc., require the optimisation of several detector parameters like; the size of the active area, the number of channels and the integration time. The influence of some of these parameters can be calculated by means of montecarlo simulations. In this paper the influence of these parameters on the measurement error is investigated by mean of numerical simulations.AB-Note-2004-016CERN-AB-Note-2004-016oai:cds.cern.ch:7108252004-02-18 |
spellingShingle | Accelerators and Storage Rings Bravin, Enrico Statistical Effects in Beam Profile Monitors |
title | Statistical Effects in Beam Profile Monitors |
title_full | Statistical Effects in Beam Profile Monitors |
title_fullStr | Statistical Effects in Beam Profile Monitors |
title_full_unstemmed | Statistical Effects in Beam Profile Monitors |
title_short | Statistical Effects in Beam Profile Monitors |
title_sort | statistical effects in beam profile monitors |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/710825 |
work_keys_str_mv | AT bravinenrico statisticaleffectsinbeamprofilemonitors |