Space charge in drift chambers operated with the Xe,CO2(15%) mixture

Using prototype modules of the ALICE Transition Radiation Detector we investigate space charge effects and the dependence of the pion rejection performance on the incident angle of the ionizing particle. The average pulse height distributions in the drift chambers operated with the Xe,CO2(15%) mixtu...

Descripción completa

Detalles Bibliográficos
Autor principal: Andronic, A
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/711142
_version_ 1780902648697847808
author Andronic, A
author_facet Andronic, A
author_sort Andronic, A
collection CERN
description Using prototype modules of the ALICE Transition Radiation Detector we investigate space charge effects and the dependence of the pion rejection performance on the incident angle of the ionizing particle. The average pulse height distributions in the drift chambers operated with the Xe,CO2(15%) mixture provide quantitative information on the gas gain reduction due to space charge accumulating during the drift of the primary ionization. Our results demonstrate that the pion rejection performance of a TRD is better for tracks which are not at normal incidence to the anode wires. We present detailed simulations of detector signals, which reproduce the measurements and lend strong support to our interpretation of the measurements in terms of space charge effects.
id cern-711142
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7111422019-09-30T06:29:59Zhttp://cds.cern.ch/record/711142engAndronic, ASpace charge in drift chambers operated with the Xe,CO2(15%) mixtureOther Fields of PhysicsUsing prototype modules of the ALICE Transition Radiation Detector we investigate space charge effects and the dependence of the pion rejection performance on the incident angle of the ionizing particle. The average pulse height distributions in the drift chambers operated with the Xe,CO2(15%) mixture provide quantitative information on the gas gain reduction due to space charge accumulating during the drift of the primary ionization. Our results demonstrate that the pion rejection performance of a TRD is better for tracks which are not at normal incidence to the anode wires. We present detailed simulations of detector signals, which reproduce the measurements and lend strong support to our interpretation of the measurements in terms of space charge effects.physics/0402043oai:cds.cern.ch:7111422004-02-09
spellingShingle Other Fields of Physics
Andronic, A
Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title_full Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title_fullStr Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title_full_unstemmed Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title_short Space charge in drift chambers operated with the Xe,CO2(15%) mixture
title_sort space charge in drift chambers operated with the xe,co2(15%) mixture
topic Other Fields of Physics
url http://cds.cern.ch/record/711142
work_keys_str_mv AT andronica spacechargeindriftchambersoperatedwiththexeco215mixture