Cargando…

Backsplash Testbeam results for the SPD

A small fraction of the cascade developed in a calorimeter by the primary particle is emitted backward as radiation often called backsplash. A testbeam with electrons and pions has been done to complete previous studies of the effect of backsplash on the SPD (Scintillator Pad Detector), positioned j...

Descripción completa

Detalles Bibliográficos
Autores principales: Aguiló, E, Ballabriga-Sune, Rafael, Calvo, M, Garrido, L, Gascón, D, Graciani, R, Graugès-Pous, E, Peralta, D, Vilasís, X, Xirgu, X
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/712333
_version_ 1780902663301365760
author Aguiló, E
Ballabriga-Sune, Rafael
Calvo, M
Garrido, L
Gascón, D
Graciani, R
Graugès-Pous, E
Peralta, D
Vilasís, X
Xirgu, X
author_facet Aguiló, E
Ballabriga-Sune, Rafael
Calvo, M
Garrido, L
Gascón, D
Graciani, R
Graugès-Pous, E
Peralta, D
Vilasís, X
Xirgu, X
author_sort Aguiló, E
collection CERN
description A small fraction of the cascade developed in a calorimeter by the primary particle is emitted backward as radiation often called backsplash. A testbeam with electrons and pions has been done to complete previous studies of the effect of backsplash on the SPD (Scintillator Pad Detector), positioned just before the Preshower and ECAL system. The measurements and their comparison with GEANT3 and EGS4 simulations are presented in this note.
id cern-712333
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7123332019-09-30T06:29:59Zhttp://cds.cern.ch/record/712333engAguiló, EBallabriga-Sune, RafaelCalvo, MGarrido, LGascón, DGraciani, RGraugès-Pous, EPeralta, DVilasís, XXirgu, XBacksplash Testbeam results for the SPDDetectors and Experimental TechniquesA small fraction of the cascade developed in a calorimeter by the primary particle is emitted backward as radiation often called backsplash. A testbeam with electrons and pions has been done to complete previous studies of the effect of backsplash on the SPD (Scintillator Pad Detector), positioned just before the Preshower and ECAL system. The measurements and their comparison with GEANT3 and EGS4 simulations are presented in this note.LHCb-2004-011oai:cds.cern.ch:7123332004-02-20
spellingShingle Detectors and Experimental Techniques
Aguiló, E
Ballabriga-Sune, Rafael
Calvo, M
Garrido, L
Gascón, D
Graciani, R
Graugès-Pous, E
Peralta, D
Vilasís, X
Xirgu, X
Backsplash Testbeam results for the SPD
title Backsplash Testbeam results for the SPD
title_full Backsplash Testbeam results for the SPD
title_fullStr Backsplash Testbeam results for the SPD
title_full_unstemmed Backsplash Testbeam results for the SPD
title_short Backsplash Testbeam results for the SPD
title_sort backsplash testbeam results for the spd
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/712333
work_keys_str_mv AT aguiloe backsplashtestbeamresultsforthespd
AT ballabrigasunerafael backsplashtestbeamresultsforthespd
AT calvom backsplashtestbeamresultsforthespd
AT garridol backsplashtestbeamresultsforthespd
AT gascond backsplashtestbeamresultsforthespd
AT gracianir backsplashtestbeamresultsforthespd
AT graugespouse backsplashtestbeamresultsforthespd
AT peraltad backsplashtestbeamresultsforthespd
AT vilasisx backsplashtestbeamresultsforthespd
AT xirgux backsplashtestbeamresultsforthespd