Cargando…
Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger
In this note we present the radiation hardness tests performed on the Agilent HFBR-772BP ribbon optical transmitter. It carries data between the muon detector and the muon trigger. We irradiated it with a proton beam of 250 MeV/c at the Paul Scherrer Institute in December 2003. The component works w...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/722198 |
_version_ | 1780903623215022080 |
---|---|
author | Aslanides, Elie Cachemiche, J P Cogan, J Dinkespiler, B Duval, P Y Le Gac, R Leroy, O Liotard, P L Menouni, M Tocco, L Tsaregorodtsev, A Yu |
author_facet | Aslanides, Elie Cachemiche, J P Cogan, J Dinkespiler, B Duval, P Y Le Gac, R Leroy, O Liotard, P L Menouni, M Tocco, L Tsaregorodtsev, A Yu |
author_sort | Aslanides, Elie |
collection | CERN |
description | In this note we present the radiation hardness tests performed on the Agilent HFBR-772BP ribbon optical transmitter. It carries data between the muon detector and the muon trigger. We irradiated it with a proton beam of 250 MeV/c at the Paul Scherrer Institute in December 2003. The component works within its specification up to a total dose of ~15 kRad, corresponding to an integrated flux of 2.5 10^11 p/cm2. This limit is a factor 7 above the total dose expected for the muon frond-end electronics after 10 years of operation. The cross-section for single event upsets is equal to (4.5+-10.1)10^{-10} cm2 per single optical link. The corresponding inefficiency on the level-0 muon trigger is below 10^-10 and therefore negligible. This component match well the requirements of the trigger interface implemented in the muon fond-end electronics. |
id | cern-722198 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7221982019-09-30T06:29:59Zhttp://cds.cern.ch/record/722198engAslanides, ElieCachemiche, J PCogan, JDinkespiler, BDuval, P YLe Gac, RLeroy, OLiotard, P LMenouni, MTocco, LTsaregorodtsev, A YuRadiation hardness of the optical ribbon transmitter for the level-0 muon triggerDetectors and Experimental TechniquesIn this note we present the radiation hardness tests performed on the Agilent HFBR-772BP ribbon optical transmitter. It carries data between the muon detector and the muon trigger. We irradiated it with a proton beam of 250 MeV/c at the Paul Scherrer Institute in December 2003. The component works within its specification up to a total dose of ~15 kRad, corresponding to an integrated flux of 2.5 10^11 p/cm2. This limit is a factor 7 above the total dose expected for the muon frond-end electronics after 10 years of operation. The cross-section for single event upsets is equal to (4.5+-10.1)10^{-10} cm2 per single optical link. The corresponding inefficiency on the level-0 muon trigger is below 10^-10 and therefore negligible. This component match well the requirements of the trigger interface implemented in the muon fond-end electronics.LHCb-2004-013oai:cds.cern.ch:7221982004-03-09 |
spellingShingle | Detectors and Experimental Techniques Aslanides, Elie Cachemiche, J P Cogan, J Dinkespiler, B Duval, P Y Le Gac, R Leroy, O Liotard, P L Menouni, M Tocco, L Tsaregorodtsev, A Yu Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title | Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title_full | Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title_fullStr | Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title_full_unstemmed | Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title_short | Radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
title_sort | radiation hardness of the optical ribbon transmitter for the level-0 muon trigger |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/722198 |
work_keys_str_mv | AT aslanideselie radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT cachemichejp radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT coganj radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT dinkespilerb radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT duvalpy radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT legacr radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT leroyo radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT liotardpl radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT menounim radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT toccol radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger AT tsaregorodtsevayu radiationhardnessoftheopticalribbontransmitterforthelevel0muontrigger |