Cargando…

Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors

With an updated, flexible, highly efficient and easily installed system we obtained accurate refractivity (n-1) values. This system is a refractometer based on a Fabry-Perot interferometer and was used to monitor the refractivity of DELPHI RICH Cherenkov radiators near the VUV region. By using a Pt-...

Descripción completa

Detalles Bibliográficos
Autores principales: Filippas-Tassos, A, Davenport, M, Fokitis, E, Maltezos, S, Patrinos, K
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-583X(02)01291-0
http://cds.cern.ch/record/724634
_version_ 1780903673293963264
author Filippas-Tassos, A
Davenport, M
Fokitis, E
Maltezos, S
Patrinos, K
author_facet Filippas-Tassos, A
Davenport, M
Fokitis, E
Maltezos, S
Patrinos, K
author_sort Filippas-Tassos, A
collection CERN
description With an updated, flexible, highly efficient and easily installed system we obtained accurate refractivity (n-1) values. This system is a refractometer based on a Fabry-Perot interferometer and was used to monitor the refractivity of DELPHI RICH Cherenkov radiators near the VUV region. By using a Pt-Ne spectral lamp and improved alignment and temperature control, the refractivities of C//5F//1//2 and C//4F//1 //0 have been monitored since 1996. With this light source, selected to have large coherence lengths, we can extract the refractivity at several wavelengths from one data set only. The estimated errors of the refractivity measurements are less than 1.2%, and depend on wavelength and the type of gas used. The various parameters affecting the accuracy of the refractometer are also discussed. Finally, results from special sample refractivity measurements of the liquid radiator (C//6F//1//4) in its gas phase, are presented.
id cern-724634
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-7246342019-09-30T06:29:59Zdoi:10.1016/S0168-583X(02)01291-0http://cds.cern.ch/record/724634engFilippas-Tassos, ADavenport, MFokitis, EMaltezos, SPatrinos, KPrecision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectorsDetectors and Experimental TechniquesWith an updated, flexible, highly efficient and easily installed system we obtained accurate refractivity (n-1) values. This system is a refractometer based on a Fabry-Perot interferometer and was used to monitor the refractivity of DELPHI RICH Cherenkov radiators near the VUV region. By using a Pt-Ne spectral lamp and improved alignment and temperature control, the refractivities of C//5F//1//2 and C//4F//1 //0 have been monitored since 1996. With this light source, selected to have large coherence lengths, we can extract the refractivity at several wavelengths from one data set only. The estimated errors of the refractivity measurements are less than 1.2%, and depend on wavelength and the type of gas used. The various parameters affecting the accuracy of the refractometer are also discussed. Finally, results from special sample refractivity measurements of the liquid radiator (C//6F//1//4) in its gas phase, are presented.oai:cds.cern.ch:7246342002
spellingShingle Detectors and Experimental Techniques
Filippas-Tassos, A
Davenport, M
Fokitis, E
Maltezos, S
Patrinos, K
Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title_full Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title_fullStr Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title_full_unstemmed Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title_short Precision measurements of gas refractivity by means of a Fabry-Perot interferometer illustrated by the monitoring of radiator refractivity in the DELPHI RICH detectors
title_sort precision measurements of gas refractivity by means of a fabry-perot interferometer illustrated by the monitoring of radiator refractivity in the delphi rich detectors
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-583X(02)01291-0
http://cds.cern.ch/record/724634
work_keys_str_mv AT filippastassosa precisionmeasurementsofgasrefractivitybymeansofafabryperotinterferometerillustratedbythemonitoringofradiatorrefractivityinthedelphirichdetectors
AT davenportm precisionmeasurementsofgasrefractivitybymeansofafabryperotinterferometerillustratedbythemonitoringofradiatorrefractivityinthedelphirichdetectors
AT fokitise precisionmeasurementsofgasrefractivitybymeansofafabryperotinterferometerillustratedbythemonitoringofradiatorrefractivityinthedelphirichdetectors
AT maltezoss precisionmeasurementsofgasrefractivitybymeansofafabryperotinterferometerillustratedbythemonitoringofradiatorrefractivityinthedelphirichdetectors
AT patrinosk precisionmeasurementsofgasrefractivitybymeansofafabryperotinterferometerillustratedbythemonitoringofradiatorrefractivityinthedelphirichdetectors