Performance of an MDT cosmic test stand: a Monte Carlo evaluation

The high level of mechanical accuracy in the wire location represents one of the main characteristics of the MDT chambers. The X-ray measurements performed at CERN have certified this accuracy; almost all the measured chambers have an r.m.s. respect to the nominal position below 20 mm. It has been a...

Descripción completa

Detalles Bibliográficos
Autores principales: Bagnaia, P, Bini, C, Ciapetti, G, De Salvo, A, Di Girolamo, A, Solfaroli, E
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/724763
_version_ 1780903676932521984
author Bagnaia, P
Bini, C
Ciapetti, G
De Salvo, A
Di Girolamo, A
Solfaroli, E
author_facet Bagnaia, P
Bini, C
Ciapetti, G
De Salvo, A
Di Girolamo, A
Solfaroli, E
author_sort Bagnaia, P
collection CERN
description The high level of mechanical accuracy in the wire location represents one of the main characteristics of the MDT chambers. The X-ray measurements performed at CERN have certified this accuracy; almost all the measured chambers have an r.m.s. respect to the nominal position below 20 mm. It has been also observed that, leaving free, in the fit to the measured wire grid, few global parameters, like the relative distance, the rotation and the angle between multilayers (chamber mechanical parameters), we can obtain a substantial improvement (up to 5-7 mm) in the wire r.m.s. that can boost the ultimate precision of the Atlas muon spectrometer. Only a small (10-15%) fraction of all MDTs can be X-ray inspected at the CERN Tomograph [2], but all the chambers are expected to be certified in a cosmic rays stand. We can therefore try to optimize the chamber geometrical parameters from the analysis of the cosmic rays data. The aim of this note is the Monte Carlo evaluation of the performance of a simple cosmic rays test facility, looking in particular to the resolution that can be obtained in the measurements of the chamber geometrical parameters.
id cern-724763
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7247632019-09-30T06:29:59Zhttp://cds.cern.ch/record/724763engBagnaia, PBini, CCiapetti, GDe Salvo, ADi Girolamo, ASolfaroli, EPerformance of an MDT cosmic test stand: a Monte Carlo evaluationDetectors and Experimental TechniquesThe high level of mechanical accuracy in the wire location represents one of the main characteristics of the MDT chambers. The X-ray measurements performed at CERN have certified this accuracy; almost all the measured chambers have an r.m.s. respect to the nominal position below 20 mm. It has been also observed that, leaving free, in the fit to the measured wire grid, few global parameters, like the relative distance, the rotation and the angle between multilayers (chamber mechanical parameters), we can obtain a substantial improvement (up to 5-7 mm) in the wire r.m.s. that can boost the ultimate precision of the Atlas muon spectrometer. Only a small (10-15%) fraction of all MDTs can be X-ray inspected at the CERN Tomograph [2], but all the chambers are expected to be certified in a cosmic rays stand. We can therefore try to optimize the chamber geometrical parameters from the analysis of the cosmic rays data. The aim of this note is the Monte Carlo evaluation of the performance of a simple cosmic rays test facility, looking in particular to the resolution that can be obtained in the measurements of the chamber geometrical parameters.ATL-MUON-2004-014oai:cds.cern.ch:7247632004-03-19
spellingShingle Detectors and Experimental Techniques
Bagnaia, P
Bini, C
Ciapetti, G
De Salvo, A
Di Girolamo, A
Solfaroli, E
Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title_full Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title_fullStr Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title_full_unstemmed Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title_short Performance of an MDT cosmic test stand: a Monte Carlo evaluation
title_sort performance of an mdt cosmic test stand: a monte carlo evaluation
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/724763
work_keys_str_mv AT bagnaiap performanceofanmdtcosmicteststandamontecarloevaluation
AT binic performanceofanmdtcosmicteststandamontecarloevaluation
AT ciapettig performanceofanmdtcosmicteststandamontecarloevaluation
AT desalvoa performanceofanmdtcosmicteststandamontecarloevaluation
AT digirolamoa performanceofanmdtcosmicteststandamontecarloevaluation
AT solfarolie performanceofanmdtcosmicteststandamontecarloevaluation