Cargando…
Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer
The RPC chambers in the L3 forward-backward muon spectrometer have been operational from 1994 to the end of LEP running. After dismantling of the L3 detector some of the RPCs modules have been transported to Napoli where their performance has been re-measured with cosmic rays. Results of long-term p...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(03)01343-3 http://cds.cern.ch/record/725915 |
_version_ | 1780903724729761792 |
---|---|
author | Alviggi, M G Caprio, M A Carlino, G Conventi, F De Asmundis, R Della Pietra, M Della Volpe, D Iengo, P Paolucci, P Patricelli, S Piccolo, D Sciacca, C Sehkniadze, G |
author_facet | Alviggi, M G Caprio, M A Carlino, G Conventi, F De Asmundis, R Della Pietra, M Della Volpe, D Iengo, P Paolucci, P Patricelli, S Piccolo, D Sciacca, C Sehkniadze, G |
author_sort | Alviggi, M G |
collection | CERN |
description | The RPC chambers in the L3 forward-backward muon spectrometer have been operational from 1994 to the end of LEP running. After dismantling of the L3 detector some of the RPCs modules have been transported to Napoli where their performance has been re-measured with cosmic rays. Results of long-term performance in the LEP environment and of laboratory tests with cosmic rays will be presented. One of the 20 tested chambers, the one with the worst performances, was opened. The chamber was inspected with microscope and also a chemical analysis of the oil coating was performed. We will report in detail about this analysis. |
id | cern-725915 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-7259152019-09-30T06:29:59Zdoi:10.1016/S0168-9002(03)01343-3http://cds.cern.ch/record/725915engAlviggi, M GCaprio, M ACarlino, GConventi, FDe Asmundis, RDella Pietra, MDella Volpe, DIengo, PPaolucci, PPatricelli, SPiccolo, DSciacca, CSehkniadze, GResults of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometerDetectors and Experimental TechniquesThe RPC chambers in the L3 forward-backward muon spectrometer have been operational from 1994 to the end of LEP running. After dismantling of the L3 detector some of the RPCs modules have been transported to Napoli where their performance has been re-measured with cosmic rays. Results of long-term performance in the LEP environment and of laboratory tests with cosmic rays will be presented. One of the 20 tested chambers, the one with the worst performances, was opened. The chamber was inspected with microscope and also a chemical analysis of the oil coating was performed. We will report in detail about this analysis.oai:cds.cern.ch:7259152003 |
spellingShingle | Detectors and Experimental Techniques Alviggi, M G Caprio, M A Carlino, G Conventi, F De Asmundis, R Della Pietra, M Della Volpe, D Iengo, P Paolucci, P Patricelli, S Piccolo, D Sciacca, C Sehkniadze, G Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title | Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title_full | Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title_fullStr | Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title_full_unstemmed | Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title_short | Results of long-term performance and subsequent laboratory tests of RPCs of the L3 forward-backward muon spectrometer |
title_sort | results of long-term performance and subsequent laboratory tests of rpcs of the l3 forward-backward muon spectrometer |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/S0168-9002(03)01343-3 http://cds.cern.ch/record/725915 |
work_keys_str_mv | AT alviggimg resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT caprioma resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT carlinog resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT conventif resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT deasmundisr resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT dellapietram resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT dellavolped resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT iengop resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT paoluccip resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT patricellis resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT piccolod resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT sciaccac resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer AT sehkniadzeg resultsoflongtermperformanceandsubsequentlaboratorytestsofrpcsofthel3forwardbackwardmuonspectrometer |