Cargando…

The RPC system for the CMS experiment at the LHC

The CMS detector at the LHC has a redundant muon system. Two independent muon systems are used in the L1 trigger. One of them is based on wire chambers, the other on RPC detectors. Properly combining the answers of the two systems results in a highly efficient L1 trigger with high flexibility from t...

Descripción completa

Detalles Bibliográficos
Autores principales: Abbrescia, M, Altieri, S, Belli, G, Bruno, G, Colaleo, A, Guida, R, Iaselli, G, Loddo, F, Maggi, M, Marangelli, B, Natali, S, Nuzzo, S, Pugliese, G, Ranieri, A, Romano, F
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:https://dx.doi.org/10.1016/S0168-9002(03)01336-6
http://cds.cern.ch/record/725919
_version_ 1780903725589594112
author Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Guida, R
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Romano, F
author_facet Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Guida, R
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Romano, F
author_sort Abbrescia, M
collection CERN
description The CMS detector at the LHC has a redundant muon system. Two independent muon systems are used in the L1 trigger. One of them is based on wire chambers, the other on RPC detectors. Properly combining the answers of the two systems results in a highly efficient L1 trigger with high flexibility from the point of view of rate control. Simulation results show, however, that the RPC system suffers from false triggers caused by coincidence of spurious hits. System improvements, which could avoid oiling the chambers, are possible. RPCs have also proved to be very useful for muon track reconstruction.
id cern-725919
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-7259192019-09-30T06:29:59Zdoi:10.1016/S0168-9002(03)01336-6http://cds.cern.ch/record/725919engAbbrescia, MAltieri, SBelli, GBruno, GColaleo, AGuida, RIaselli, GLoddo, FMaggi, MMarangelli, BNatali, SNuzzo, SPugliese, GRanieri, ARomano, FThe RPC system for the CMS experiment at the LHCDetectors and Experimental TechniquesThe CMS detector at the LHC has a redundant muon system. Two independent muon systems are used in the L1 trigger. One of them is based on wire chambers, the other on RPC detectors. Properly combining the answers of the two systems results in a highly efficient L1 trigger with high flexibility from the point of view of rate control. Simulation results show, however, that the RPC system suffers from false triggers caused by coincidence of spurious hits. System improvements, which could avoid oiling the chambers, are possible. RPCs have also proved to be very useful for muon track reconstruction.oai:cds.cern.ch:7259192003
spellingShingle Detectors and Experimental Techniques
Abbrescia, M
Altieri, S
Belli, G
Bruno, G
Colaleo, A
Guida, R
Iaselli, G
Loddo, F
Maggi, M
Marangelli, B
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Romano, F
The RPC system for the CMS experiment at the LHC
title The RPC system for the CMS experiment at the LHC
title_full The RPC system for the CMS experiment at the LHC
title_fullStr The RPC system for the CMS experiment at the LHC
title_full_unstemmed The RPC system for the CMS experiment at the LHC
title_short The RPC system for the CMS experiment at the LHC
title_sort rpc system for the cms experiment at the lhc
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/S0168-9002(03)01336-6
http://cds.cern.ch/record/725919
work_keys_str_mv AT abbresciam therpcsystemforthecmsexperimentatthelhc
AT altieris therpcsystemforthecmsexperimentatthelhc
AT bellig therpcsystemforthecmsexperimentatthelhc
AT brunog therpcsystemforthecmsexperimentatthelhc
AT colaleoa therpcsystemforthecmsexperimentatthelhc
AT guidar therpcsystemforthecmsexperimentatthelhc
AT iasellig therpcsystemforthecmsexperimentatthelhc
AT loddof therpcsystemforthecmsexperimentatthelhc
AT maggim therpcsystemforthecmsexperimentatthelhc
AT marangellib therpcsystemforthecmsexperimentatthelhc
AT natalis therpcsystemforthecmsexperimentatthelhc
AT nuzzos therpcsystemforthecmsexperimentatthelhc
AT puglieseg therpcsystemforthecmsexperimentatthelhc
AT ranieria therpcsystemforthecmsexperimentatthelhc
AT romanof therpcsystemforthecmsexperimentatthelhc
AT abbresciam rpcsystemforthecmsexperimentatthelhc
AT altieris rpcsystemforthecmsexperimentatthelhc
AT bellig rpcsystemforthecmsexperimentatthelhc
AT brunog rpcsystemforthecmsexperimentatthelhc
AT colaleoa rpcsystemforthecmsexperimentatthelhc
AT guidar rpcsystemforthecmsexperimentatthelhc
AT iasellig rpcsystemforthecmsexperimentatthelhc
AT loddof rpcsystemforthecmsexperimentatthelhc
AT maggim rpcsystemforthecmsexperimentatthelhc
AT marangellib rpcsystemforthecmsexperimentatthelhc
AT natalis rpcsystemforthecmsexperimentatthelhc
AT nuzzos rpcsystemforthecmsexperimentatthelhc
AT puglieseg rpcsystemforthecmsexperimentatthelhc
AT ranieria rpcsystemforthecmsexperimentatthelhc
AT romanof rpcsystemforthecmsexperimentatthelhc