Cargando…
Splice testing for LHC quadrupole magnets
Electrical splices between NbTi Rutherford type cables need to be made for the LHC IR inner triplet quadrupoles. Splices between magnets as well as internal to the magnets are necessary. Various splice configurations, solders, and fluxes have been considered. Testing of these splices at cryogenic te...
Autores principales: | Barzi, E, Bossert, R, Fehér, S, Kashikhin, V V, Kerby, J S, Lamm, M J, Orris, D, Ray, G, Tartaglia, M, Zlobin, A V |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TASC.2003.812654 http://cds.cern.ch/record/725953 |
Ejemplares similares
-
Mechanical design and analysis of LHC inner triplet quadrupole magnets at Fermilab
por: Andreev, N, et al.
Publicado: (2000) -
Magnetic Field Measurements of the LHC Inner Triplet Quadrupoles Produced at Fermilab
por: Velev, Gueorgui V, et al.
Publicado: (2004) -
Busbar studies for the LHC interaction region quadrupoles
por: Bauer, P, et al.
Publicado: (2001) -
Field quality measurements of the LQXB inner triplet quadrupoles for LHC
por: Velev, G V, et al.
Publicado: (2005) -
Development and test of LARP technological quadrupole (TQC) magnet
por: Feher, S, et al.