Cargando…

Comparison of FEA Calculations with Cryostat Dummy Weight Test Results

Extensive Finite Element analyses were performed to determine the loads and stresses acting on the EB and Barrel during assembly and in its final configuration. Up to now it has been difficult to verify the FEA results due to the unusual compression at the inner radius shims has resulted in larger t...

Descripción completa

Detalles Bibliográficos
Autor principal: Guarino, V
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/727934
_version_ 1780903798118547456
author Guarino, V
author_facet Guarino, V
author_sort Guarino, V
collection CERN
description Extensive Finite Element analyses were performed to determine the loads and stresses acting on the EB and Barrel during assembly and in its final configuration. Up to now it has been difficult to verify the FEA results due to the unusual compression at the inner radius shims has resulted in larger than anticipated deflections. The cryostat dummy load test offers the first real chance for a direct comparison between the deflections of the Tilecal and the FEA model. By comparing the difference in position of the FM's before the cryostat load was applied and afterwards it is possible to eliminate all other variables and compare directly with the FEA model. This paper will present a comparison between the FEA model and the survey measurements for when the cryostat dummy weight load was applied at 32 modules and 46 modules in place.
id cern-727934
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7279342019-09-30T06:29:59Zhttp://cds.cern.ch/record/727934engGuarino, VComparison of FEA Calculations with Cryostat Dummy Weight Test ResultsDetectors and Experimental TechniquesExtensive Finite Element analyses were performed to determine the loads and stresses acting on the EB and Barrel during assembly and in its final configuration. Up to now it has been difficult to verify the FEA results due to the unusual compression at the inner radius shims has resulted in larger than anticipated deflections. The cryostat dummy load test offers the first real chance for a direct comparison between the deflections of the Tilecal and the FEA model. By comparing the difference in position of the FM's before the cryostat load was applied and afterwards it is possible to eliminate all other variables and compare directly with the FEA model. This paper will present a comparison between the FEA model and the survey measurements for when the cryostat dummy weight load was applied at 32 modules and 46 modules in place.ATL-TILECAL-2004-005oai:cds.cern.ch:7279342004-04-02
spellingShingle Detectors and Experimental Techniques
Guarino, V
Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title_full Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title_fullStr Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title_full_unstemmed Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title_short Comparison of FEA Calculations with Cryostat Dummy Weight Test Results
title_sort comparison of fea calculations with cryostat dummy weight test results
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/727934
work_keys_str_mv AT guarinov comparisonoffeacalculationswithcryostatdummyweighttestresults