Cargando…

Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN

Considerable effort is spent at CERN on magnetic alignment measurements of main lattice LHC dipoles, including field direction, curved axis shape and position of in-built correctors, essential to verify the geometry of the assembly and to guarantee correct installation w.r.t. the reference beam orbi...

Descripción completa

Detalles Bibliográficos
Autores principales: Bottura, L, Buzio, M, Coccoli, M, Deferne, G, García-Pérez, J, Smirnov, N
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2004.829054
http://cds.cern.ch/record/732296
_version_ 1780903880154939392
author Bottura, L
Buzio, M
Coccoli, M
Deferne, G
García-Pérez, J
Smirnov, N
author_facet Bottura, L
Buzio, M
Coccoli, M
Deferne, G
García-Pérez, J
Smirnov, N
author_sort Bottura, L
collection CERN
description Considerable effort is spent at CERN on magnetic alignment measurements of main lattice LHC dipoles, including field direction, curved axis shape and position of in-built correctors, essential to verify the geometry of the assembly and to guarantee correct installation w.r.t. the reference beam orbit. The current baseline includes measurements of a statistically relevant percentage of cold masses and cryostated magnets before, during and after cryogenic tests. For this, we use a range of scanning probes based either on harmonic coils or fixed coils in AC mode, with laser and telescope trackers to measure position w.r.t. cryostat fiducials. The dipole is usually powered in "quadrupole mode" to create a convenient magnetic reference. In this paper, we first recall objectives, equipment and methods. Then, we report the status of the test activities, showing results obtained on the first pre-series dipoles, including cross-checks of various measurement systems and correlation between measurements at room and cryogenic temperatures.
id cern-732296
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7322962023-05-31T13:21:18Zdoi:10.1109/TASC.2004.829054http://cds.cern.ch/record/732296engBottura, LBuzio, MCoccoli, MDeferne, GGarcía-Pérez, JSmirnov, NMagnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERNAccelerators and Storage RingsConsiderable effort is spent at CERN on magnetic alignment measurements of main lattice LHC dipoles, including field direction, curved axis shape and position of in-built correctors, essential to verify the geometry of the assembly and to guarantee correct installation w.r.t. the reference beam orbit. The current baseline includes measurements of a statistically relevant percentage of cold masses and cryostated magnets before, during and after cryogenic tests. For this, we use a range of scanning probes based either on harmonic coils or fixed coils in AC mode, with laser and telescope trackers to measure position w.r.t. cryostat fiducials. The dipole is usually powered in "quadrupole mode" to create a convenient magnetic reference. In this paper, we first recall objectives, equipment and methods. Then, we report the status of the test activities, showing results obtained on the first pre-series dipoles, including cross-checks of various measurement systems and correlation between measurements at room and cryogenic temperatures.LHC-Project-Report-700CERN-LHC-Project-Report-700oai:cds.cern.ch:7322962004-04-02
spellingShingle Accelerators and Storage Rings
Bottura, L
Buzio, M
Coccoli, M
Deferne, G
García-Pérez, J
Smirnov, N
Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title_full Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title_fullStr Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title_full_unstemmed Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title_short Magnetic Alignment Measurements at Room and Cryogenic Temperature of LHC Cryodipoles and Associated Correctors at CERN
title_sort magnetic alignment measurements at room and cryogenic temperature of lhc cryodipoles and associated correctors at cern
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1109/TASC.2004.829054
http://cds.cern.ch/record/732296
work_keys_str_mv AT bottural magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern
AT buziom magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern
AT coccolim magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern
AT deferneg magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern
AT garciaperezj magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern
AT smirnovn magneticalignmentmeasurementsatroomandcryogenictemperatureoflhccryodipolesandassociatedcorrectorsatcern