Cargando…

Measurements of quadrupole frequency shift below transition

Measurements of the quadrupole frequency shift done at 14 GeV/c with a single bunch for different bunch lengths and intensities are compared with estimations based on the nonlinear dependence of frequency on the amplitude of oscillation and the present model of the longitudinal SPS impedance. Analys...

Descripción completa

Detalles Bibliográficos
Autores principales: Bohl, T, Linnecar, Trevor Paul R, Shaposhnikova, Elena, Tückmantel, Joachim
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/734817
_version_ 1780903942291456000
author Bohl, T
Linnecar, Trevor Paul R
Shaposhnikova, Elena
Tückmantel, Joachim
author_facet Bohl, T
Linnecar, Trevor Paul R
Shaposhnikova, Elena
Tückmantel, Joachim
author_sort Bohl, T
collection CERN
description Measurements of the quadrupole frequency shift done at 14 GeV/c with a single bunch for different bunch lengths and intensities are compared with estimations based on the nonlinear dependence of frequency on the amplitude of oscillation and the present model of the longitudinal SPS impedance. Analysis of the measurements shows that the quadrupole frequency shift is mainly related to bunch length variation. Due to the relatively low energy of the beam the contribution coming from the space charge was expected to be non-negligible.
id cern-734817
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7348172019-09-30T06:29:59Zhttp://cds.cern.ch/record/734817engBohl, TLinnecar, Trevor Paul RShaposhnikova, ElenaTückmantel, JoachimMeasurements of quadrupole frequency shift below transitionAccelerators and Storage RingsMeasurements of the quadrupole frequency shift done at 14 GeV/c with a single bunch for different bunch lengths and intensities are compared with estimations based on the nonlinear dependence of frequency on the amplitude of oscillation and the present model of the longitudinal SPS impedance. Analysis of the measurements shows that the quadrupole frequency shift is mainly related to bunch length variation. Due to the relatively low energy of the beam the contribution coming from the space charge was expected to be non-negligible.AB-Note-2004-047CERN-AB-Note-2004-047oai:cds.cern.ch:7348172004-05-17
spellingShingle Accelerators and Storage Rings
Bohl, T
Linnecar, Trevor Paul R
Shaposhnikova, Elena
Tückmantel, Joachim
Measurements of quadrupole frequency shift below transition
title Measurements of quadrupole frequency shift below transition
title_full Measurements of quadrupole frequency shift below transition
title_fullStr Measurements of quadrupole frequency shift below transition
title_full_unstemmed Measurements of quadrupole frequency shift below transition
title_short Measurements of quadrupole frequency shift below transition
title_sort measurements of quadrupole frequency shift below transition
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/734817
work_keys_str_mv AT bohlt measurementsofquadrupolefrequencyshiftbelowtransition
AT linnecartrevorpaulr measurementsofquadrupolefrequencyshiftbelowtransition
AT shaposhnikovaelena measurementsofquadrupolefrequencyshiftbelowtransition
AT tuckmanteljoachim measurementsofquadrupolefrequencyshiftbelowtransition