Cargando…

Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation

In summer 2003, a Monitored Drift Tube chamber of type BIL has been exposed to a 100 GeV muon beam in the X5 area at CERN. The chamber was installed on a rotating support in the Gamma Irradiation Facility GIF, where a $^{137}$Cs radioactive source irradiates the detectors with an intense photon flux...

Descripción completa

Detalles Bibliográficos
Autores principales: Cirilli, M, Di Domenico, A, Di Girolamo, A, Fiore, S, Lacava, F, Luci, C, Pontecorvo, L, Salvatore, D, Tonazzo, A, Zimmermann, S
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/735200
_version_ 1780903948191793152
author Cirilli, M
Di Domenico, A
Di Girolamo, A
Fiore, S
Lacava, F
Luci, C
Pontecorvo, L
Salvatore, D
Tonazzo, A
Zimmermann, S
author_facet Cirilli, M
Di Domenico, A
Di Girolamo, A
Fiore, S
Lacava, F
Luci, C
Pontecorvo, L
Salvatore, D
Tonazzo, A
Zimmermann, S
author_sort Cirilli, M
collection CERN
description In summer 2003, a Monitored Drift Tube chamber of type BIL has been exposed to a 100 GeV muon beam in the X5 area at CERN. The chamber was installed on a rotating support in the Gamma Irradiation Facility GIF, where a $^{137}$Cs radioactive source irradiates the detectors with an intense photon flux. A system of lead filters that can be moved in front of the source allows the users to tune the intensity of the flux. Detailed studies on the determination of the TDC spectrum parameters were performed, also as a function of the background conditions. The rotating support allowed to change the angle of the chamber with respect to the beam. The set of data taken at different orientation was used to perform a preliminary analysis of the conventional autocalibration procedure in absence of background.
id cern-735200
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7352002019-09-30T06:29:59Zhttp://cds.cern.ch/record/735200engCirilli, MDi Domenico, ADi Girolamo, AFiore, SLacava, FLuci, CPontecorvo, LSalvatore, DTonazzo, AZimmermann, SResults from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relationDetectors and Experimental TechniquesIn summer 2003, a Monitored Drift Tube chamber of type BIL has been exposed to a 100 GeV muon beam in the X5 area at CERN. The chamber was installed on a rotating support in the Gamma Irradiation Facility GIF, where a $^{137}$Cs radioactive source irradiates the detectors with an intense photon flux. A system of lead filters that can be moved in front of the source allows the users to tune the intensity of the flux. Detailed studies on the determination of the TDC spectrum parameters were performed, also as a function of the background conditions. The rotating support allowed to change the angle of the chamber with respect to the beam. The set of data taken at different orientation was used to perform a preliminary analysis of the conventional autocalibration procedure in absence of background.ATL-MUON-2004-028ATL-COM-MUON-2004-009CERN-ATL-COM-MUON-2004-009oai:cds.cern.ch:7352002004
spellingShingle Detectors and Experimental Techniques
Cirilli, M
Di Domenico, A
Di Girolamo, A
Fiore, S
Lacava, F
Luci, C
Pontecorvo, L
Salvatore, D
Tonazzo, A
Zimmermann, S
Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title_full Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title_fullStr Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title_full_unstemmed Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title_short Results from the 2003 beam test of a MDT BIL chamber: systematic uncertainties on the TDC spectrum parameters and on the space-time relation
title_sort results from the 2003 beam test of a mdt bil chamber: systematic uncertainties on the tdc spectrum parameters and on the space-time relation
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/735200
work_keys_str_mv AT cirillim resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT didomenicoa resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT digirolamoa resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT fiores resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT lacavaf resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT lucic resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT pontecorvol resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT salvatored resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT tonazzoa resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation
AT zimmermanns resultsfromthe2003beamtestofamdtbilchambersystematicuncertaintiesonthetdcspectrumparametersandonthespacetimerelation