Cargando…
Pick-Up and Orbit Measurement System for CNAO
The future Italian National Centre for Oncological Hadron therapy (CNAO) will host an accelerator complex whose design is based on the PIMMS project. This paper describes the closed orbit measurement system (beam position monitor and its associated electronics modules) of the synchrotron, from the d...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/735388 |
_version_ | 1780903949720616960 |
---|---|
author | Caldara, M Soby, L Tan, J |
author_facet | Caldara, M Soby, L Tan, J |
author_sort | Caldara, M |
collection | CERN |
description | The future Italian National Centre for Oncological Hadron therapy (CNAO) will host an accelerator complex whose design is based on the PIMMS project. This paper describes the closed orbit measurement system (beam position monitor and its associated electronics modules) of the synchrotron, from the design requirements to the prototyping. Laboratory tests show that the system is capable to satisfy the requirements, such as 60 dB of dynamic range, 0.1/0.13 mm resolution for proton/carbon ions, and low linearity errors (±0.7 %). |
id | cern-735388 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7353882019-09-30T06:29:59Zhttp://cds.cern.ch/record/735388engCaldara, MSoby, LTan, JPick-Up and Orbit Measurement System for CNAOAccelerators and Storage RingsThe future Italian National Centre for Oncological Hadron therapy (CNAO) will host an accelerator complex whose design is based on the PIMMS project. This paper describes the closed orbit measurement system (beam position monitor and its associated electronics modules) of the synchrotron, from the design requirements to the prototyping. Laboratory tests show that the system is capable to satisfy the requirements, such as 60 dB of dynamic range, 0.1/0.13 mm resolution for proton/carbon ions, and low linearity errors (±0.7 %).AB-Note-2004-048CERN-AB-Note-2004-048oai:cds.cern.ch:7353882004-05-19 |
spellingShingle | Accelerators and Storage Rings Caldara, M Soby, L Tan, J Pick-Up and Orbit Measurement System for CNAO |
title | Pick-Up and Orbit Measurement System for CNAO |
title_full | Pick-Up and Orbit Measurement System for CNAO |
title_fullStr | Pick-Up and Orbit Measurement System for CNAO |
title_full_unstemmed | Pick-Up and Orbit Measurement System for CNAO |
title_short | Pick-Up and Orbit Measurement System for CNAO |
title_sort | pick-up and orbit measurement system for cnao |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/735388 |
work_keys_str_mv | AT caldaram pickupandorbitmeasurementsystemforcnao AT sobyl pickupandorbitmeasurementsystemforcnao AT tanj pickupandorbitmeasurementsystemforcnao |