Cargando…

Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration

A new fitting method, using pp to X+Z events, with Z to e+e-, has been developped to calibrate the ATLAS electromagnetic calorimeter. Validity tests were carried on Pythia events, and the method was tested on the DC1 simulation data. These results can be extrapolated to the ATLAS configuration. The...

Descripción completa

Detalles Bibliográficos
Autor principal: Djama, F
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/745592
_version_ 1780904107739971584
author Djama, F
author_facet Djama, F
author_sort Djama, F
collection CERN
description A new fitting method, using pp to X+Z events, with Z to e+e-, has been developped to calibrate the ATLAS electromagnetic calorimeter. Validity tests were carried on Pythia events, and the method was tested on the DC1 simulation data. These results can be extrapolated to the ATLAS configuration. The forseen 0.3 % precision on the calibration coefficients of 448 Delta eta x Delta phi regions could be achieved within two to three days, and monitored on this basis, at low luminosity.
id cern-745592
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7455922019-09-30T06:29:59Zhttp://cds.cern.ch/record/745592engDjama, FUsing $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter CalibrationDetectors and Experimental TechniquesA new fitting method, using pp to X+Z events, with Z to e+e-, has been developped to calibrate the ATLAS electromagnetic calorimeter. Validity tests were carried on Pythia events, and the method was tested on the DC1 simulation data. These results can be extrapolated to the ATLAS configuration. The forseen 0.3 % precision on the calibration coefficients of 448 Delta eta x Delta phi regions could be achieved within two to three days, and monitored on this basis, at low luminosity.ATL-LARG-2004-008oai:cds.cern.ch:7455922004-06-23
spellingShingle Detectors and Experimental Techniques
Djama, F
Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title_full Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title_fullStr Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title_full_unstemmed Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title_short Using $Z^0 \rightarrow e^+ e^-$ for Electromagnetic Calorimeter Calibration
title_sort using $z^0 \rightarrow e^+ e^-$ for electromagnetic calorimeter calibration
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/745592
work_keys_str_mv AT djamaf usingz0rightarroweeforelectromagneticcalorimetercalibration