Cargando…

Armando System Measurements at R-306 FY 2003 Report

This report details some of the measurements made by Bechtel Nevada (BN) to characterize the Armando radiographic detection system and marks the completion of the R-306 Armando System Characterization milestone. The measurements, made in July 2003, utilized the Cygnus pulse power machine, which was...

Descripción completa

Detalles Bibliográficos
Autores principales: Lutz, S S, Baker, S A
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/747071
_version_ 1780904142639726592
author Lutz, S S
Baker, S A
author_facet Lutz, S S
Baker, S A
author_sort Lutz, S S
collection CERN
description This report details some of the measurements made by Bechtel Nevada (BN) to characterize the Armando radiographic detection system and marks the completion of the R-306 Armando System Characterization milestone. The measurements, made in July 2003, utilized the Cygnus pulse power machine, which was assembled at the Los Alamos National Laboratory (LANL) Firing Site R-306. This report describes the test configuration used and the findings concerning the following Armando radiographic detection system issues for source spot size, mirror vs. pellicle performance, scintillator configuration evaluation, resolution and reproducibility, off-axis scatter contribution, and source spectra reproducibility.
id cern-747071
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-7470712019-09-30T06:29:59Zhttp://cds.cern.ch/record/747071engLutz, S SBaker, S AArmando System Measurements at R-306 FY 2003 ReportDetectors and Experimental TechniquesThis report details some of the measurements made by Bechtel Nevada (BN) to characterize the Armando radiographic detection system and marks the completion of the R-306 Armando System Characterization milestone. The measurements, made in July 2003, utilized the Cygnus pulse power machine, which was assembled at the Los Alamos National Laboratory (LANL) Firing Site R-306. This report describes the test configuration used and the findings concerning the following Armando radiographic detection system issues for source spot size, mirror vs. pellicle performance, scintillator configuration evaluation, resolution and reproducibility, off-axis scatter contribution, and source spectra reproducibility.oai:cds.cern.ch:7470712003-09-01
spellingShingle Detectors and Experimental Techniques
Lutz, S S
Baker, S A
Armando System Measurements at R-306 FY 2003 Report
title Armando System Measurements at R-306 FY 2003 Report
title_full Armando System Measurements at R-306 FY 2003 Report
title_fullStr Armando System Measurements at R-306 FY 2003 Report
title_full_unstemmed Armando System Measurements at R-306 FY 2003 Report
title_short Armando System Measurements at R-306 FY 2003 Report
title_sort armando system measurements at r-306 fy 2003 report
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/747071
work_keys_str_mv AT lutzss armandosystemmeasurementsatr306fy2003report
AT bakersa armandosystemmeasurementsatr306fy2003report