Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions
The gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensio...
Autores principales: | , , , |
---|---|
Lenguaje: | rus |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/747539 |
_version_ | 1780904160309280768 |
---|---|
author | Kasarinov, N Y Gall, A Kalagin, I V Kazacha, V I |
author_facet | Kasarinov, N Y Gall, A Kalagin, I V Kazacha, V I |
author_sort | Kasarinov, N Y |
collection | CERN |
description | The gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensions by current signals from the scanner needle are adduced. The method of the emittance recovery for axial-symmetric ion beam is set for the case when the space charge effect is essential. The algorithm for tuning of the quadrupole lenses in the injection channel of the cyclotron DC-72 for obtaining the axial-symmetric ion beam is proposed. The evaluations of the expected accuracy of the proposed method for the emittance recovery have been carried out. |
id | cern-747539 |
institution | Organización Europea para la Investigación Nuclear |
language | rus |
publishDate | 2002 |
record_format | invenio |
spelling | cern-7475392019-09-30T06:29:59Zhttp://cds.cern.ch/record/747539rusKasarinov, N YGall, AKalagin, I VKazacha, V IMethod of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensionsAccelerators and Storage RingsThe gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensions by current signals from the scanner needle are adduced. The method of the emittance recovery for axial-symmetric ion beam is set for the case when the space charge effect is essential. The algorithm for tuning of the quadrupole lenses in the injection channel of the cyclotron DC-72 for obtaining the axial-symmetric ion beam is proposed. The evaluations of the expected accuracy of the proposed method for the emittance recovery have been carried out.JINR-R9-2002-266oai:cds.cern.ch:7475392002 |
spellingShingle | Accelerators and Storage Rings Kasarinov, N Y Gall, A Kalagin, I V Kazacha, V I Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title | Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title_full | Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title_fullStr | Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title_full_unstemmed | Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title_short | Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
title_sort | method of the ion beam emittance measurement in the injection beam line of dc-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/747539 |
work_keys_str_mv | AT kasarinovny methodoftheionbeamemittancemeasurementintheinjectionbeamlineofdc72cyclotroninthepresenceofitsspacechargeusingthescannertodeterminebeamdimensions AT galla methodoftheionbeamemittancemeasurementintheinjectionbeamlineofdc72cyclotroninthepresenceofitsspacechargeusingthescannertodeterminebeamdimensions AT kalaginiv methodoftheionbeamemittancemeasurementintheinjectionbeamlineofdc72cyclotroninthepresenceofitsspacechargeusingthescannertodeterminebeamdimensions AT kazachavi methodoftheionbeamemittancemeasurementintheinjectionbeamlineofdc72cyclotroninthepresenceofitsspacechargeusingthescannertodeterminebeamdimensions |