Cargando…
Method of the ion beam emittance measurement in the injection beam line of DC-72 cyclotron in the presence of its space charge using the scanner to determine beam dimensions
The gradient method for measuring the transversal emittance of a high current ion beam in the injection channel of the cyclotron DC-72 is considered. The standard scanner is proposed for measuring the transversal dimensions of the beam. The formulae for determination of the mean square beam dimensio...
Autores principales: | Kasarinov, N Y, Gall, A, Kalagin, I V, Kazacha, V I |
---|---|
Lenguaje: | rus |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/747539 |