Cargando…

Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System

The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, <100>, <110> and <111>) for use as electron-beam transmission windows in a KrF excimer laser system...

Descripción completa

Detalles Bibliográficos
Autores principales: Gentile, C A, Fan, H M, Hartfield, J W, Hawryluk, R J, Hegeler, F, Heitzenroeder, P J, Jun, C H, Ku, L P, Lamarche, P H, Myers, M C, Parker, J J, Parsells, R F, Payen, M, Raftopoulos, S, Sethian, J D
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/747733
_version_ 1780904183341252608
author Gentile, C A
Fan, H M
Hartfield, J W
Hawryluk, R J
Hegeler, F
Heitzenroeder, P J
Jun, C H
Ku, L P
Lamarche, P H
Myers, M C
Parker, J J
Parsells, R F
Payen, M
Raftopoulos, S
Sethian, J D
author_facet Gentile, C A
Fan, H M
Hartfield, J W
Hawryluk, R J
Hegeler, F
Heitzenroeder, P J
Jun, C H
Ku, L P
Lamarche, P H
Myers, M C
Parker, J J
Parsells, R F
Payen, M
Raftopoulos, S
Sethian, J D
author_sort Gentile, C A
collection CERN
description The Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, <100>, <110> and <111>) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W centre dot cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated with 500 nm thin-film silicon nitride (Si sub 3 N sub 4), has been fabricated. The window consists of 81 square panes with a thickness of 0.019 mm +- 0.001 mm. Stiffened (orthogonal) sections are 0.065 mm in width and 0.500 mm thick (approximate). Appended drawing (Figure 1) depicts the window configuration. Assessment of silicon (and silicon nitride) material properties and CAD modeling and analysis of the window design suggest that silicon may be a viable solution to inherent parameters and constraints.
id cern-747733
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-7477332019-09-30T06:29:59Zhttp://cds.cern.ch/record/747733engGentile, C AFan, H MHartfield, J WHawryluk, R JHegeler, FHeitzenroeder, P JJun, C HKu, L PLamarche, P HMyers, M CParker, J JParsells, R FPayen, MRaftopoulos, SSethian, J DDevelopment of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser SystemCondensed MatterThe Princeton Plasma Physics Laboratory (PPPL), in collaboration with the Naval Research Laboratory (NRL), is currently investigating various novel materials (single crystal silicon, <100>, <110> and <111>) for use as electron-beam transmission windows in a KrF excimer laser system. The primary function of the window is to isolate the active medium (excimer gas) from the excitation mechanism (field-emission diodes). Chosen window geometry must accommodate electron energy transfer greater than 80% (750 keV), while maintaining structural integrity during mechanical load (1.3 to 2.0 atm base pressure differential, approximate 0.5 atm cyclic pressure amplitude, 5 Hz repetition rate) and thermal load across the entire hibachi area (approximate 0.9 W centre dot cm superscript ''-2''). In addition, the window must be chemically resistant to attack by fluorine free-radicals (hydrofluoric acid, secondary). In accordance with these structural, functional, and operational parameters, a 22.4 mm square silicon prototype window, coated with 500 nm thin-film silicon nitride (Si sub 3 N sub 4), has been fabricated. The window consists of 81 square panes with a thickness of 0.019 mm +- 0.001 mm. Stiffened (orthogonal) sections are 0.065 mm in width and 0.500 mm thick (approximate). Appended drawing (Figure 1) depicts the window configuration. Assessment of silicon (and silicon nitride) material properties and CAD modeling and analysis of the window design suggest that silicon may be a viable solution to inherent parameters and constraints.oai:cds.cern.ch:7477332002-11-21
spellingShingle Condensed Matter
Gentile, C A
Fan, H M
Hartfield, J W
Hawryluk, R J
Hegeler, F
Heitzenroeder, P J
Jun, C H
Ku, L P
Lamarche, P H
Myers, M C
Parker, J J
Parsells, R F
Payen, M
Raftopoulos, S
Sethian, J D
Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title_full Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title_fullStr Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title_full_unstemmed Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title_short Development of a Silicon Based Electron Beam Transmission Window for Use in a KrF Excimer Laser System
title_sort development of a silicon based electron beam transmission window for use in a krf excimer laser system
topic Condensed Matter
url http://cds.cern.ch/record/747733
work_keys_str_mv AT gentileca developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT fanhm developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT hartfieldjw developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT hawrylukrj developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT hegelerf developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT heitzenroederpj developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT junch developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT kulp developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT lamarcheph developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT myersmc developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT parkerjj developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT parsellsrf developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT payenm developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT raftopouloss developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem
AT sethianjd developmentofasiliconbasedelectronbeamtransmissionwindowforuseinakrfexcimerlasersystem