Cargando…

The estimation of beam losses due to charge exchange with the residual gas in a cyclotron

The estimation of beam losses due to charge exchange with the residual gas in a cyclotron intended for acceleration of sub 8 sub 4 Kr sup 1 sup 7 sup + ions from energy 0.003 to 2.4 MeV/nucleon is presented. The transmission factor of sub 8 sub 4 Kr sup 1 sup 7 sup + ions is greater than 60 % if ave...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalinichenko, V V, Karamysheva, G A
Lenguaje:rus
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/747824
_version_ 1780904188532752384
author Kalinichenko, V V
Karamysheva, G A
author_facet Kalinichenko, V V
Karamysheva, G A
author_sort Kalinichenko, V V
collection CERN
description The estimation of beam losses due to charge exchange with the residual gas in a cyclotron intended for acceleration of sub 8 sub 4 Kr sup 1 sup 7 sup + ions from energy 0.003 to 2.4 MeV/nucleon is presented. The transmission factor of sub 8 sub 4 Kr sup 1 sup 7 sup + ions is greater than 60 % if average pressure is smaller than 10 sup - sup 6 Torr for designed accelerating voltage V = 50 kV and 9 centre dot 10 sup - sup 7 Torr for V = 40 kV. Accelerating voltage decrease to 40 kV follows to beam intensity increase by 8 % from initial intensity in comparison with the designed value.
id cern-747824
institution Organización Europea para la Investigación Nuclear
language rus
publishDate 2002
record_format invenio
spelling cern-7478242019-09-30T06:29:59Zhttp://cds.cern.ch/record/747824rusKalinichenko, V VKaramysheva, G AThe estimation of beam losses due to charge exchange with the residual gas in a cyclotronAccelerators and Storage RingsThe estimation of beam losses due to charge exchange with the residual gas in a cyclotron intended for acceleration of sub 8 sub 4 Kr sup 1 sup 7 sup + ions from energy 0.003 to 2.4 MeV/nucleon is presented. The transmission factor of sub 8 sub 4 Kr sup 1 sup 7 sup + ions is greater than 60 % if average pressure is smaller than 10 sup - sup 6 Torr for designed accelerating voltage V = 50 kV and 9 centre dot 10 sup - sup 7 Torr for V = 40 kV. Accelerating voltage decrease to 40 kV follows to beam intensity increase by 8 % from initial intensity in comparison with the designed value.JINR-R9-2002-58oai:cds.cern.ch:7478242002
spellingShingle Accelerators and Storage Rings
Kalinichenko, V V
Karamysheva, G A
The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title_full The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title_fullStr The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title_full_unstemmed The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title_short The estimation of beam losses due to charge exchange with the residual gas in a cyclotron
title_sort estimation of beam losses due to charge exchange with the residual gas in a cyclotron
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/747824
work_keys_str_mv AT kalinichenkovv theestimationofbeamlossesduetochargeexchangewiththeresidualgasinacyclotron
AT karamyshevaga theestimationofbeamlossesduetochargeexchangewiththeresidualgasinacyclotron
AT kalinichenkovv estimationofbeamlossesduetochargeexchangewiththeresidualgasinacyclotron
AT karamyshevaga estimationofbeamlossesduetochargeexchangewiththeresidualgasinacyclotron