Cargando…
Verification criteria on the reliability of personal dosimetric services from x and gamma radiations
The paper presents the methods used by Working Group ENEA-EDP (Experts in Personal Dosimetry) to control the reliability of the Dosimetric Services operating in Italy and asking for the above controls on voluntary basis. Testing and irradiation test methods are explained as well as the evaluation cr...
Autores principales: | , , |
---|---|
Lenguaje: | ita |
Publicado: |
1990
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/747871 |
_version_ | 1780904195916824576 |
---|---|
author | Borasi, G Benco, A Kaftal, S |
author_facet | Borasi, G Benco, A Kaftal, S |
author_sort | Borasi, G |
collection | CERN |
description | The paper presents the methods used by Working Group ENEA-EDP (Experts in Personal Dosimetry) to control the reliability of the Dosimetric Services operating in Italy and asking for the above controls on voluntary basis. Testing and irradiation test methods are explained as well as the evaluation criteria. The paper includes suggestions and guide-lines to gain the status of 'Reliable Service'. Technical equipment and operating procedures needed to pass the test are also illustrated. |
id | cern-747871 |
institution | Organización Europea para la Investigación Nuclear |
language | ita |
publishDate | 1990 |
record_format | invenio |
spelling | cern-7478712019-09-30T06:29:59Zhttp://cds.cern.ch/record/747871itaBorasi, GBenco, AKaftal, SVerification criteria on the reliability of personal dosimetric services from x and gamma radiationsHealth Physics and Radiation EffectsThe paper presents the methods used by Working Group ENEA-EDP (Experts in Personal Dosimetry) to control the reliability of the Dosimetric Services operating in Italy and asking for the above controls on voluntary basis. Testing and irradiation test methods are explained as well as the evaluation criteria. The paper includes suggestions and guide-lines to gain the status of 'Reliable Service'. Technical equipment and operating procedures needed to pass the test are also illustrated.ENEA-RT-AMB-90-18oai:cds.cern.ch:7478711990 |
spellingShingle | Health Physics and Radiation Effects Borasi, G Benco, A Kaftal, S Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title | Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title_full | Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title_fullStr | Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title_full_unstemmed | Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title_short | Verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
title_sort | verification criteria on the reliability of personal dosimetric services from x and gamma radiations |
topic | Health Physics and Radiation Effects |
url | http://cds.cern.ch/record/747871 |
work_keys_str_mv | AT borasig verificationcriteriaonthereliabilityofpersonaldosimetricservicesfromxandgammaradiations AT bencoa verificationcriteriaonthereliabilityofpersonaldosimetricservicesfromxandgammaradiations AT kaftals verificationcriteriaonthereliabilityofpersonaldosimetricservicesfromxandgammaradiations |