Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spi...
Autor principal: | |
---|---|
Lenguaje: | pol |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/748320 |
_version_ | 1780904242411732992 |
---|---|
author | Peimel-Stuglik, Z |
author_facet | Peimel-Stuglik, Z |
author_sort | Peimel-Stuglik, Z |
collection | CERN |
description | The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life. |
id | cern-748320 |
institution | Organización Europea para la Investigación Nuclear |
language | pol |
publishDate | 2001 |
record_format | invenio |
spelling | cern-7483202019-09-30T06:29:59Zhttp://cds.cern.ch/record/748320polPeimel-Stuglik, ZDosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma raysDetectors and Experimental TechniquesThe usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.INCT-11-B-01oai:cds.cern.ch:7483202001 |
spellingShingle | Detectors and Experimental Techniques Peimel-Stuglik, Z Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title | Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title_full | Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title_fullStr | Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title_full_unstemmed | Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title_short | Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays |
title_sort | dosimetric response of united, commercially available cta foils for sup 6 sup 0 co gamma rays |