Cargando…

Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays

The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spi...

Descripción completa

Detalles Bibliográficos
Autor principal: Peimel-Stuglik, Z
Lenguaje:pol
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/748320
_version_ 1780904242411732992
author Peimel-Stuglik, Z
author_facet Peimel-Stuglik, Z
author_sort Peimel-Stuglik, Z
collection CERN
description The usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.
id cern-748320
institution Organización Europea para la Investigación Nuclear
language pol
publishDate 2001
record_format invenio
spelling cern-7483202019-09-30T06:29:59Zhttp://cds.cern.ch/record/748320polPeimel-Stuglik, ZDosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma raysDetectors and Experimental TechniquesThe usefulness of two kinds of untinted CTA foils: Fuji CTR-125 dosimetric foil and technical CTA-T foil, produced by 'Zaklady Chemiczne, 'Gorzow Wielkopolski' as support for light-sensitive layers of amateur photo-films, for sup 6 sup 0 Co gamma ray dosimetry was investigated. In spite of rather bad physical parameters of the technical foil (spread of foil thickness, high and different initial absorbance) the dosimetric response of both foils for sup 6 sup 0 Co gamma rays was similar. The CTA-T foil can be used for routine dosimetry providing that dosimetric signals have to be calculated exactly as recommended by the ASTM (American Society for Testing and Materials) standard, i.e. as the difference of absorbance of irradiated and (the same) non-irradiated foil. Any other approach may lead to high errors of dose evaluation. The last is true also for other CTA foils, especially after long self-life.INCT-11-B-01oai:cds.cern.ch:7483202001
spellingShingle Detectors and Experimental Techniques
Peimel-Stuglik, Z
Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title_full Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title_fullStr Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title_full_unstemmed Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title_short Dosimetric response of united, commercially available CTA foils for sup 6 sup 0 Co gamma rays
title_sort dosimetric response of united, commercially available cta foils for sup 6 sup 0 co gamma rays
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/748320
work_keys_str_mv AT peimelstuglikz dosimetricresponseofunitedcommerciallyavailablectafoilsforsup6sup0cogammarays