Cargando…
Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Servi...
Autores principales: | , |
---|---|
Lenguaje: | pol |
Publicado: |
2001
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/748321 |
_version_ | 1780904242623545344 |
---|---|
author | Peimel-Stuglik, Z Fabisiak, S |
author_facet | Peimel-Stuglik, Z Fabisiak, S |
author_sort | Peimel-Stuglik, Z |
collection | CERN |
description | The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food. |
id | cern-748321 |
institution | Organización Europea para la Investigación Nuclear |
language | pol |
publishDate | 2001 |
record_format | invenio |
spelling | cern-7483212019-09-30T06:29:59Zhttp://cds.cern.ch/record/748321polPeimel-Stuglik, ZFabisiak, SAlanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGyDetectors and Experimental TechniquesThe usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food.INCT-10-B-01oai:cds.cern.ch:7483212001 |
spellingShingle | Detectors and Experimental Techniques Peimel-Stuglik, Z Fabisiak, S Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title | Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title_full | Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title_fullStr | Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title_full_unstemmed | Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title_short | Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy |
title_sort | alanine-epr dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kgy |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/748321 |
work_keys_str_mv | AT peimelstuglikz alanineeprdosimetryformeasurementsofionizingradiationabsorbeddosesintherange0510kgy AT fabisiaks alanineeprdosimetryformeasurementsofionizingradiationabsorbeddosesintherange0510kgy |