Cargando…

Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy

The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Servi...

Descripción completa

Detalles Bibliográficos
Autores principales: Peimel-Stuglik, Z, Fabisiak, S
Lenguaje:pol
Publicado: 2001
Materias:
Acceso en línea:http://cds.cern.ch/record/748321
_version_ 1780904242623545344
author Peimel-Stuglik, Z
Fabisiak, S
author_facet Peimel-Stuglik, Z
Fabisiak, S
author_sort Peimel-Stuglik, Z
collection CERN
description The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food.
id cern-748321
institution Organización Europea para la Investigación Nuclear
language pol
publishDate 2001
record_format invenio
spelling cern-7483212019-09-30T06:29:59Zhttp://cds.cern.ch/record/748321polPeimel-Stuglik, ZFabisiak, SAlanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGyDetectors and Experimental TechniquesThe usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food.INCT-10-B-01oai:cds.cern.ch:7483212001
spellingShingle Detectors and Experimental Techniques
Peimel-Stuglik, Z
Fabisiak, S
Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title_full Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title_fullStr Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title_full_unstemmed Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title_short Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy
title_sort alanine-epr dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kgy
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/748321
work_keys_str_mv AT peimelstuglikz alanineeprdosimetryformeasurementsofionizingradiationabsorbeddosesintherange0510kgy
AT fabisiaks alanineeprdosimetryformeasurementsofionizingradiationabsorbeddosesintherange0510kgy