Cargando…

Mass Measurement on the rp-Process Waiting Point 72Kr

The mass of one of the three major waiting points in the astrophysical rp-process 72Kr was measured for the first time with the Penning trap mass spectrometer ISOLTRAP. The measurement yielded a relative mass uncertainty of delta m/m = 1.2x10-7 (delta m=8keV). Other Kr isotopes, also needed for astr...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodríguez, D, Kolhinen, V, Audi, G, Äystö, J, Beck, D, Blaum, K, Bollen, G, Herfurth, F, Jokinen, A, Kellerbauer, A G, Kluge, H J, Oinonen, M, Schatz, H, Sauvan, E, Schwarz, S
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/771687
_version_ 1780904278266740736
author Rodríguez, D
Kolhinen, V
Audi, G
Äystö, J
Beck, D
Blaum, K
Bollen, G
Herfurth, F
Jokinen, A
Kellerbauer, A G
Kluge, H J
Oinonen, M
Schatz, H
Sauvan, E
Schwarz, S
author_facet Rodríguez, D
Kolhinen, V
Audi, G
Äystö, J
Beck, D
Blaum, K
Bollen, G
Herfurth, F
Jokinen, A
Kellerbauer, A G
Kluge, H J
Oinonen, M
Schatz, H
Sauvan, E
Schwarz, S
author_sort Rodríguez, D
collection CERN
description The mass of one of the three major waiting points in the astrophysical rp-process 72Kr was measured for the first time with the Penning trap mass spectrometer ISOLTRAP. The measurement yielded a relative mass uncertainty of delta m/m = 1.2x10-7 (delta m=8keV). Other Kr isotopes, also needed for astrophysical calculations, were measured with more than one order of magnitude improved accuracy. We use the ISOLTRAP masses of 72-74Kr to reanalyse the role of the 72Kr waiting point in the rp-process during X-ray bursts.
id cern-771687
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7716872019-09-30T06:29:59Zhttp://cds.cern.ch/record/771687engRodríguez, DKolhinen, VAudi, GÄystö, JBeck, DBlaum, KBollen, GHerfurth, FJokinen, AKellerbauer, A GKluge, H JOinonen, MSchatz, HSauvan, ESchwarz, SMass Measurement on the rp-Process Waiting Point 72KrNuclear PhysicsThe mass of one of the three major waiting points in the astrophysical rp-process 72Kr was measured for the first time with the Penning trap mass spectrometer ISOLTRAP. The measurement yielded a relative mass uncertainty of delta m/m = 1.2x10-7 (delta m=8keV). Other Kr isotopes, also needed for astrophysical calculations, were measured with more than one order of magnitude improved accuracy. We use the ISOLTRAP masses of 72-74Kr to reanalyse the role of the 72Kr waiting point in the rp-process during X-ray bursts.EXT-2004-073GSI-2004-16oai:cds.cern.ch:7716872004-07-14
spellingShingle Nuclear Physics
Rodríguez, D
Kolhinen, V
Audi, G
Äystö, J
Beck, D
Blaum, K
Bollen, G
Herfurth, F
Jokinen, A
Kellerbauer, A G
Kluge, H J
Oinonen, M
Schatz, H
Sauvan, E
Schwarz, S
Mass Measurement on the rp-Process Waiting Point 72Kr
title Mass Measurement on the rp-Process Waiting Point 72Kr
title_full Mass Measurement on the rp-Process Waiting Point 72Kr
title_fullStr Mass Measurement on the rp-Process Waiting Point 72Kr
title_full_unstemmed Mass Measurement on the rp-Process Waiting Point 72Kr
title_short Mass Measurement on the rp-Process Waiting Point 72Kr
title_sort mass measurement on the rp-process waiting point 72kr
topic Nuclear Physics
url http://cds.cern.ch/record/771687
work_keys_str_mv AT rodriguezd massmeasurementontherpprocesswaitingpoint72kr
AT kolhinenv massmeasurementontherpprocesswaitingpoint72kr
AT audig massmeasurementontherpprocesswaitingpoint72kr
AT aystoj massmeasurementontherpprocesswaitingpoint72kr
AT beckd massmeasurementontherpprocesswaitingpoint72kr
AT blaumk massmeasurementontherpprocesswaitingpoint72kr
AT bolleng massmeasurementontherpprocesswaitingpoint72kr
AT herfurthf massmeasurementontherpprocesswaitingpoint72kr
AT jokinena massmeasurementontherpprocesswaitingpoint72kr
AT kellerbauerag massmeasurementontherpprocesswaitingpoint72kr
AT klugehj massmeasurementontherpprocesswaitingpoint72kr
AT oinonenm massmeasurementontherpprocesswaitingpoint72kr
AT schatzh massmeasurementontherpprocesswaitingpoint72kr
AT sauvane massmeasurementontherpprocesswaitingpoint72kr
AT schwarzs massmeasurementontherpprocesswaitingpoint72kr