Cargando…
Test results from a prototype lead tungstate crystal calorimeter with vacuum phototriode readout for the CMS experiment
Tests of a prototype for the electromagnetic calorimeter (ECAL) of the compact muon solenoid experiment (CMS) at the large hadron collider are described. The basic unit for the endcap ECAL in CMS is a 'supercrystal' of 25 lead tungstate crystals. Results are presented from tests of the fir...
Autores principales: | Apollonio, M, Barber, G, Bell, K W, Britton, D I, Brooke, J J, Brown, R M, Bourotte, J, Camanzi, B, Cockerill, D J A, Davies, G, Devitsin, E G, Gninenko, S N, Golubev, N A, Goussev, Y, Grafström, P, Haguenauer, Maurice, Head, R, Heath, H, Hobson, P R, Inyakin, A V, Katchanov, V A, Kirsanov, M M, Lintern, A L, Lodge, A, McLeod, E, Nash, S, Newbold, D, Ukhanov, M, Postoev, V E, Patalakha, D I, Presland, A, Probert, M, Seez, Christopher J, Semeniouk, I N, Seliverstov, D M, Smith, B, Sproston, M, Tapper, R J, Tchuiko, B |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/S0168-9002(01)01987-8 http://cds.cern.ch/record/772071 |
Ejemplares similares
-
The performance of prototype vacuum phototriodes in the first full sized supercrystal array for the CMS ECAL endcaps
por: Apollonio, M, et al.
Publicado: (2004) -
Radiation hardness, excess noise factor and short-term gain instability of vacuum phototriodes for the operation in pseudorapidity range 15 < eta < 30 at CMS ECAL
por: Blinnikov, Yu S, et al.
Publicado: (2003) -
The Vacuum Phototriodes for the CMS Electromagnetic Calorimeter
por: Brown, R, et al.
Publicado: (2001) -
The development of vacuum phototriodes for the CMS electromagnetic calorimeter
por: Bell, K W, et al.
Publicado: (2001) -
Vacuum phototriodes for the CMS electromagnetic calorimeter endcap
por: Bell, K W, et al.
Publicado: (2004)