A wide-range direction neutron spectrometer
A new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with differ...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/772534 |
_version_ | 1780904292160372736 |
---|---|
author | Luszik-Bhadra, M D'Errico, F Hecker, O Matzke, M |
author_facet | Luszik-Bhadra, M D'Errico, F Hecker, O Matzke, M |
author_sort | Luszik-Bhadra, M |
collection | CERN |
description | A new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with different energy and direction distributions of neutron fluence. The direction-integrated fluence spectra agree fairly well with reference spectra. In all cases, the ambient and personal dose equivalent values calculated from measured direction-differential spectra are within 35% of the reference values. Independent measurements of the directional dose equivalent were performed with a directional dose equivalent monitor based on superheated drop detectors. |
id | cern-772534 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-7725342019-09-30T06:29:59Zhttp://cds.cern.ch/record/772534engLuszik-Bhadra, MD'Errico, FHecker, OMatzke, MA wide-range direction neutron spectrometerDetectors and Experimental TechniquesA new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with different energy and direction distributions of neutron fluence. The direction-integrated fluence spectra agree fairly well with reference spectra. In all cases, the ambient and personal dose equivalent values calculated from measured direction-differential spectra are within 35% of the reference values. Independent measurements of the directional dose equivalent were performed with a directional dose equivalent monitor based on superheated drop detectors.oai:cds.cern.ch:7725342002 |
spellingShingle | Detectors and Experimental Techniques Luszik-Bhadra, M D'Errico, F Hecker, O Matzke, M A wide-range direction neutron spectrometer |
title | A wide-range direction neutron spectrometer |
title_full | A wide-range direction neutron spectrometer |
title_fullStr | A wide-range direction neutron spectrometer |
title_full_unstemmed | A wide-range direction neutron spectrometer |
title_short | A wide-range direction neutron spectrometer |
title_sort | wide-range direction neutron spectrometer |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/772534 |
work_keys_str_mv | AT luszikbhadram awiderangedirectionneutronspectrometer AT derricof awiderangedirectionneutronspectrometer AT heckero awiderangedirectionneutronspectrometer AT matzkem awiderangedirectionneutronspectrometer AT luszikbhadram widerangedirectionneutronspectrometer AT derricof widerangedirectionneutronspectrometer AT heckero widerangedirectionneutronspectrometer AT matzkem widerangedirectionneutronspectrometer |