Cargando…

A wide-range direction neutron spectrometer

A new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with differ...

Descripción completa

Detalles Bibliográficos
Autores principales: Luszik-Bhadra, M, D'Errico, F, Hecker, O, Matzke, M
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/772534
_version_ 1780904292160372736
author Luszik-Bhadra, M
D'Errico, F
Hecker, O
Matzke, M
author_facet Luszik-Bhadra, M
D'Errico, F
Hecker, O
Matzke, M
author_sort Luszik-Bhadra, M
collection CERN
description A new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with different energy and direction distributions of neutron fluence. The direction-integrated fluence spectra agree fairly well with reference spectra. In all cases, the ambient and personal dose equivalent values calculated from measured direction-differential spectra are within 35% of the reference values. Independent measurements of the directional dose equivalent were performed with a directional dose equivalent monitor based on superheated drop detectors.
id cern-772534
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-7725342019-09-30T06:29:59Zhttp://cds.cern.ch/record/772534engLuszik-Bhadra, MD'Errico, FHecker, OMatzke, MA wide-range direction neutron spectrometerDetectors and Experimental TechniquesA new device is presented which has been developed for measuring the energy and direction of distribution of neutron fluence in fields of broad energy spectra (thermal to 100 MeV) and with a high background of photon, electron and muon radiation. The device was tested in reference fields with different energy and direction distributions of neutron fluence. The direction-integrated fluence spectra agree fairly well with reference spectra. In all cases, the ambient and personal dose equivalent values calculated from measured direction-differential spectra are within 35% of the reference values. Independent measurements of the directional dose equivalent were performed with a directional dose equivalent monitor based on superheated drop detectors.oai:cds.cern.ch:7725342002
spellingShingle Detectors and Experimental Techniques
Luszik-Bhadra, M
D'Errico, F
Hecker, O
Matzke, M
A wide-range direction neutron spectrometer
title A wide-range direction neutron spectrometer
title_full A wide-range direction neutron spectrometer
title_fullStr A wide-range direction neutron spectrometer
title_full_unstemmed A wide-range direction neutron spectrometer
title_short A wide-range direction neutron spectrometer
title_sort wide-range direction neutron spectrometer
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/772534
work_keys_str_mv AT luszikbhadram awiderangedirectionneutronspectrometer
AT derricof awiderangedirectionneutronspectrometer
AT heckero awiderangedirectionneutronspectrometer
AT matzkem awiderangedirectionneutronspectrometer
AT luszikbhadram widerangedirectionneutronspectrometer
AT derricof widerangedirectionneutronspectrometer
AT heckero widerangedirectionneutronspectrometer
AT matzkem widerangedirectionneutronspectrometer