Cargando…

Spatial resolution of RPC in streamer mode

In the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage an...

Descripción completa

Detalles Bibliográficos
Autores principales: Arnaldi, R, Baldit, A, Barret, V, Bastid, N, Blanchard, G, Chiavassa, E, Cortese, P, Crochet, Philippe, Dellacasa, G, De Marco, N, Drancourt, C, Dupieux, P, Espagnon, B, Ferretti, A, Forestier, B, Insa, C, Jouve, F, Gallio, M, Genoux-Lubain, A, Lamoine, L, Lefèvre, F, Manso, F, Mereu, P, Musso, A, Oppedisano, C, Piccotti, A, Roig, O, Rosnet, P, Royer, L, Saturnini, P, Scalas, E, Scomparin, E, Sigaudo, F, Vercellin, Ermanno
Lenguaje:eng
Publicado: 2002
Materias:
Acceso en línea:http://cds.cern.ch/record/773825
_version_ 1780904299547590656
author Arnaldi, R
Baldit, A
Barret, V
Bastid, N
Blanchard, G
Chiavassa, E
Cortese, P
Crochet, Philippe
Dellacasa, G
De Marco, N
Drancourt, C
Dupieux, P
Espagnon, B
Ferretti, A
Forestier, B
Insa, C
Jouve, F
Gallio, M
Genoux-Lubain, A
Lamoine, L
Lefèvre, F
Manso, F
Mereu, P
Musso, A
Oppedisano, C
Piccotti, A
Roig, O
Rosnet, P
Royer, L
Saturnini, P
Scalas, E
Scomparin, E
Sigaudo, F
Vercellin, Ermanno
author_facet Arnaldi, R
Baldit, A
Barret, V
Bastid, N
Blanchard, G
Chiavassa, E
Cortese, P
Crochet, Philippe
Dellacasa, G
De Marco, N
Drancourt, C
Dupieux, P
Espagnon, B
Ferretti, A
Forestier, B
Insa, C
Jouve, F
Gallio, M
Genoux-Lubain, A
Lamoine, L
Lefèvre, F
Manso, F
Mereu, P
Musso, A
Oppedisano, C
Piccotti, A
Roig, O
Rosnet, P
Royer, L
Saturnini, P
Scalas, E
Scomparin, E
Sigaudo, F
Vercellin, Ermanno
author_sort Arnaldi, R
collection CERN
description In the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage and to the gas mixture. However, the spatial resolution measured from the beam tests is only slightly varying with the high voltage and is close to the expected value w/sq root 12 where w is the strip pitch, for strips of 1 and 2 cm width. The probability to fire a strip as a function of the distance from the strip to the particle impact has been measured for various high voltages. A simple parametrisation of this probability has been achieved. This allows to predict, under various working condition, the cluster size distributions for RPCs with different strip widths and also to account for the effect of the particle incident angle.
id cern-773825
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2002
record_format invenio
spelling cern-7738252019-09-30T06:29:59Zhttp://cds.cern.ch/record/773825engArnaldi, RBaldit, ABarret, VBastid, NBlanchard, GChiavassa, ECortese, PCrochet, PhilippeDellacasa, GDe Marco, NDrancourt, CDupieux, PEspagnon, BFerretti, AForestier, BInsa, CJouve, FGallio, MGenoux-Lubain, ALamoine, LLefèvre, FManso, FMereu, PMusso, AOppedisano, CPiccotti, ARoig, ORosnet, PRoyer, LSaturnini, PScalas, EScomparin, ESigaudo, FVercellin, ErmannoSpatial resolution of RPC in streamer modeDetectors and Experimental TechniquesIn the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage and to the gas mixture. However, the spatial resolution measured from the beam tests is only slightly varying with the high voltage and is close to the expected value w/sq root 12 where w is the strip pitch, for strips of 1 and 2 cm width. The probability to fire a strip as a function of the distance from the strip to the particle impact has been measured for various high voltages. A simple parametrisation of this probability has been achieved. This allows to predict, under various working condition, the cluster size distributions for RPCs with different strip widths and also to account for the effect of the particle incident angle.oai:cds.cern.ch:7738252002
spellingShingle Detectors and Experimental Techniques
Arnaldi, R
Baldit, A
Barret, V
Bastid, N
Blanchard, G
Chiavassa, E
Cortese, P
Crochet, Philippe
Dellacasa, G
De Marco, N
Drancourt, C
Dupieux, P
Espagnon, B
Ferretti, A
Forestier, B
Insa, C
Jouve, F
Gallio, M
Genoux-Lubain, A
Lamoine, L
Lefèvre, F
Manso, F
Mereu, P
Musso, A
Oppedisano, C
Piccotti, A
Roig, O
Rosnet, P
Royer, L
Saturnini, P
Scalas, E
Scomparin, E
Sigaudo, F
Vercellin, Ermanno
Spatial resolution of RPC in streamer mode
title Spatial resolution of RPC in streamer mode
title_full Spatial resolution of RPC in streamer mode
title_fullStr Spatial resolution of RPC in streamer mode
title_full_unstemmed Spatial resolution of RPC in streamer mode
title_short Spatial resolution of RPC in streamer mode
title_sort spatial resolution of rpc in streamer mode
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/773825
work_keys_str_mv AT arnaldir spatialresolutionofrpcinstreamermode
AT baldita spatialresolutionofrpcinstreamermode
AT barretv spatialresolutionofrpcinstreamermode
AT bastidn spatialresolutionofrpcinstreamermode
AT blanchardg spatialresolutionofrpcinstreamermode
AT chiavassae spatialresolutionofrpcinstreamermode
AT cortesep spatialresolutionofrpcinstreamermode
AT crochetphilippe spatialresolutionofrpcinstreamermode
AT dellacasag spatialresolutionofrpcinstreamermode
AT demarcon spatialresolutionofrpcinstreamermode
AT drancourtc spatialresolutionofrpcinstreamermode
AT dupieuxp spatialresolutionofrpcinstreamermode
AT espagnonb spatialresolutionofrpcinstreamermode
AT ferrettia spatialresolutionofrpcinstreamermode
AT forestierb spatialresolutionofrpcinstreamermode
AT insac spatialresolutionofrpcinstreamermode
AT jouvef spatialresolutionofrpcinstreamermode
AT galliom spatialresolutionofrpcinstreamermode
AT genouxlubaina spatialresolutionofrpcinstreamermode
AT lamoinel spatialresolutionofrpcinstreamermode
AT lefevref spatialresolutionofrpcinstreamermode
AT mansof spatialresolutionofrpcinstreamermode
AT mereup spatialresolutionofrpcinstreamermode
AT mussoa spatialresolutionofrpcinstreamermode
AT oppedisanoc spatialresolutionofrpcinstreamermode
AT piccottia spatialresolutionofrpcinstreamermode
AT roigo spatialresolutionofrpcinstreamermode
AT rosnetp spatialresolutionofrpcinstreamermode
AT royerl spatialresolutionofrpcinstreamermode
AT saturninip spatialresolutionofrpcinstreamermode
AT scalase spatialresolutionofrpcinstreamermode
AT scomparine spatialresolutionofrpcinstreamermode
AT sigaudof spatialresolutionofrpcinstreamermode
AT vercellinermanno spatialresolutionofrpcinstreamermode