Cargando…
Spatial resolution of RPC in streamer mode
In the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage an...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2002
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/773825 |
_version_ | 1780904299547590656 |
---|---|
author | Arnaldi, R Baldit, A Barret, V Bastid, N Blanchard, G Chiavassa, E Cortese, P Crochet, Philippe Dellacasa, G De Marco, N Drancourt, C Dupieux, P Espagnon, B Ferretti, A Forestier, B Insa, C Jouve, F Gallio, M Genoux-Lubain, A Lamoine, L Lefèvre, F Manso, F Mereu, P Musso, A Oppedisano, C Piccotti, A Roig, O Rosnet, P Royer, L Saturnini, P Scalas, E Scomparin, E Sigaudo, F Vercellin, Ermanno |
author_facet | Arnaldi, R Baldit, A Barret, V Bastid, N Blanchard, G Chiavassa, E Cortese, P Crochet, Philippe Dellacasa, G De Marco, N Drancourt, C Dupieux, P Espagnon, B Ferretti, A Forestier, B Insa, C Jouve, F Gallio, M Genoux-Lubain, A Lamoine, L Lefèvre, F Manso, F Mereu, P Musso, A Oppedisano, C Piccotti, A Roig, O Rosnet, P Royer, L Saturnini, P Scalas, E Scomparin, E Sigaudo, F Vercellin, Ermanno |
author_sort | Arnaldi, R |
collection | CERN |
description | In the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage and to the gas mixture. However, the spatial resolution measured from the beam tests is only slightly varying with the high voltage and is close to the expected value w/sq root 12 where w is the strip pitch, for strips of 1 and 2 cm width. The probability to fire a strip as a function of the distance from the strip to the particle impact has been measured for various high voltages. A simple parametrisation of this probability has been achieved. This allows to predict, under various working condition, the cluster size distributions for RPCs with different strip widths and also to account for the effect of the particle incident angle. |
id | cern-773825 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2002 |
record_format | invenio |
spelling | cern-7738252019-09-30T06:29:59Zhttp://cds.cern.ch/record/773825engArnaldi, RBaldit, ABarret, VBastid, NBlanchard, GChiavassa, ECortese, PCrochet, PhilippeDellacasa, GDe Marco, NDrancourt, CDupieux, PEspagnon, BFerretti, AForestier, BInsa, CJouve, FGallio, MGenoux-Lubain, ALamoine, LLefèvre, FManso, FMereu, PMusso, AOppedisano, CPiccotti, ARoig, ORosnet, PRoyer, LSaturnini, PScalas, EScomparin, ESigaudo, FVercellin, ErmannoSpatial resolution of RPC in streamer modeDetectors and Experimental TechniquesIn the framework of an R and D program on the ALICE dimuon trigger system, the spatial resolution of Resistive Plate Chambers working in streamer mode has been investigated during beam tests. Preliminary studies with cosmic rays had evidenced a dependence of the charge profile to the high voltage and to the gas mixture. However, the spatial resolution measured from the beam tests is only slightly varying with the high voltage and is close to the expected value w/sq root 12 where w is the strip pitch, for strips of 1 and 2 cm width. The probability to fire a strip as a function of the distance from the strip to the particle impact has been measured for various high voltages. A simple parametrisation of this probability has been achieved. This allows to predict, under various working condition, the cluster size distributions for RPCs with different strip widths and also to account for the effect of the particle incident angle.oai:cds.cern.ch:7738252002 |
spellingShingle | Detectors and Experimental Techniques Arnaldi, R Baldit, A Barret, V Bastid, N Blanchard, G Chiavassa, E Cortese, P Crochet, Philippe Dellacasa, G De Marco, N Drancourt, C Dupieux, P Espagnon, B Ferretti, A Forestier, B Insa, C Jouve, F Gallio, M Genoux-Lubain, A Lamoine, L Lefèvre, F Manso, F Mereu, P Musso, A Oppedisano, C Piccotti, A Roig, O Rosnet, P Royer, L Saturnini, P Scalas, E Scomparin, E Sigaudo, F Vercellin, Ermanno Spatial resolution of RPC in streamer mode |
title | Spatial resolution of RPC in streamer mode |
title_full | Spatial resolution of RPC in streamer mode |
title_fullStr | Spatial resolution of RPC in streamer mode |
title_full_unstemmed | Spatial resolution of RPC in streamer mode |
title_short | Spatial resolution of RPC in streamer mode |
title_sort | spatial resolution of rpc in streamer mode |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/773825 |
work_keys_str_mv | AT arnaldir spatialresolutionofrpcinstreamermode AT baldita spatialresolutionofrpcinstreamermode AT barretv spatialresolutionofrpcinstreamermode AT bastidn spatialresolutionofrpcinstreamermode AT blanchardg spatialresolutionofrpcinstreamermode AT chiavassae spatialresolutionofrpcinstreamermode AT cortesep spatialresolutionofrpcinstreamermode AT crochetphilippe spatialresolutionofrpcinstreamermode AT dellacasag spatialresolutionofrpcinstreamermode AT demarcon spatialresolutionofrpcinstreamermode AT drancourtc spatialresolutionofrpcinstreamermode AT dupieuxp spatialresolutionofrpcinstreamermode AT espagnonb spatialresolutionofrpcinstreamermode AT ferrettia spatialresolutionofrpcinstreamermode AT forestierb spatialresolutionofrpcinstreamermode AT insac spatialresolutionofrpcinstreamermode AT jouvef spatialresolutionofrpcinstreamermode AT galliom spatialresolutionofrpcinstreamermode AT genouxlubaina spatialresolutionofrpcinstreamermode AT lamoinel spatialresolutionofrpcinstreamermode AT lefevref spatialresolutionofrpcinstreamermode AT mansof spatialresolutionofrpcinstreamermode AT mereup spatialresolutionofrpcinstreamermode AT mussoa spatialresolutionofrpcinstreamermode AT oppedisanoc spatialresolutionofrpcinstreamermode AT piccottia spatialresolutionofrpcinstreamermode AT roigo spatialresolutionofrpcinstreamermode AT rosnetp spatialresolutionofrpcinstreamermode AT royerl spatialresolutionofrpcinstreamermode AT saturninip spatialresolutionofrpcinstreamermode AT scalase spatialresolutionofrpcinstreamermode AT scomparine spatialresolutionofrpcinstreamermode AT sigaudof spatialresolutionofrpcinstreamermode AT vercellinermanno spatialresolutionofrpcinstreamermode |