Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
In this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2003
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/787491 |
_version_ | 1780904430726545408 |
---|---|
author | Valls, Juan Poveda, J |
author_facet | Valls, Juan Poveda, J |
author_sort | Valls, Juan |
collection | CERN |
description | In this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are compared to the single module setup with electrical read out. Both test setups show a small or negligible common mode noise picked up by the modules. Similar noise results are obtained in both setups after full calibration gain values are applied. We measure total noise values of ~1600 electrons in peak mode and ~2600 electrons in deconvolution mode. Signal to noise ratios of the order of 15 (25) for deconvolution (peak) operation modes are found. The noise occupancies on the modules have important implications for the zero suppression algorithms which the CMS Tracker FEDs will use to reduce t he data volume flowing to the DAQ. The detector signal efficiencies and noise occupancies are also shown as a function of threshold for a particular clustering algorithm. Signal efficiencies versus noise occupancy plots could also be used to grade detector modules in rods during production. |
id | cern-787491 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2003 |
record_format | invenio |
spelling | cern-7874912019-09-30T06:29:59Zhttp://cds.cern.ch/record/787491engValls, JuanPoveda, JPerformance of CMS TOB Silicon Detector Modules on a Double Sided Prototype RODDetectors and Experimental TechniquesIn this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are compared to the single module setup with electrical read out. Both test setups show a small or negligible common mode noise picked up by the modules. Similar noise results are obtained in both setups after full calibration gain values are applied. We measure total noise values of ~1600 electrons in peak mode and ~2600 electrons in deconvolution mode. Signal to noise ratios of the order of 15 (25) for deconvolution (peak) operation modes are found. The noise occupancies on the modules have important implications for the zero suppression algorithms which the CMS Tracker FEDs will use to reduce t he data volume flowing to the DAQ. The detector signal efficiencies and noise occupancies are also shown as a function of threshold for a particular clustering algorithm. Signal efficiencies versus noise occupancy plots could also be used to grade detector modules in rods during production.CMS-NOTE-2004-005oai:cds.cern.ch:7874912003-11-18 |
spellingShingle | Detectors and Experimental Techniques Valls, Juan Poveda, J Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title | Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title_full | Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title_fullStr | Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title_full_unstemmed | Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title_short | Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD |
title_sort | performance of cms tob silicon detector modules on a double sided prototype rod |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/787491 |
work_keys_str_mv | AT vallsjuan performanceofcmstobsilicondetectormodulesonadoublesidedprototyperod AT povedaj performanceofcmstobsilicondetectormodulesonadoublesidedprototyperod |