Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD

In this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are...

Descripción completa

Detalles Bibliográficos
Autores principales: Valls, Juan, Poveda, J
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/787491
_version_ 1780904430726545408
author Valls, Juan
Poveda, J
author_facet Valls, Juan
Poveda, J
author_sort Valls, Juan
collection CERN
description In this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are compared to the single module setup with electrical read out. Both test setups show a small or negligible common mode noise picked up by the modules. Similar noise results are obtained in both setups after full calibration gain values are applied. We measure total noise values of ~1600 electrons in peak mode and ~2600 electrons in deconvolution mode. Signal to noise ratios of the order of 15 (25) for deconvolution (peak) operation modes are found. The noise occupancies on the modules have important implications for the zero suppression algorithms which the CMS Tracker FEDs will use to reduce t he data volume flowing to the DAQ. The detector signal efficiencies and noise occupancies are also shown as a function of threshold for a particular clustering algorithm. Signal efficiencies versus noise occupancy plots could also be used to grade detector modules in rods during production.
id cern-787491
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-7874912019-09-30T06:29:59Zhttp://cds.cern.ch/record/787491engValls, JuanPoveda, JPerformance of CMS TOB Silicon Detector Modules on a Double Sided Prototype RODDetectors and Experimental TechniquesIn this paper we summarize results of the performance of CMS TOB silicon detector modules mounted on the first assembled double-sided rod at CERN. Results are given in terms of noise, noise occupancies, signal to noise ratios and signal efficiencies. The noise figures from the rod optical setup are compared to the single module setup with electrical read out. Both test setups show a small or negligible common mode noise picked up by the modules. Similar noise results are obtained in both setups after full calibration gain values are applied. We measure total noise values of ~1600 electrons in peak mode and ~2600 electrons in deconvolution mode. Signal to noise ratios of the order of 15 (25) for deconvolution (peak) operation modes are found. The noise occupancies on the modules have important implications for the zero suppression algorithms which the CMS Tracker FEDs will use to reduce t he data volume flowing to the DAQ. The detector signal efficiencies and noise occupancies are also shown as a function of threshold for a particular clustering algorithm. Signal efficiencies versus noise occupancy plots could also be used to grade detector modules in rods during production.CMS-NOTE-2004-005oai:cds.cern.ch:7874912003-11-18
spellingShingle Detectors and Experimental Techniques
Valls, Juan
Poveda, J
Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title_full Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title_fullStr Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title_full_unstemmed Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title_short Performance of CMS TOB Silicon Detector Modules on a Double Sided Prototype ROD
title_sort performance of cms tob silicon detector modules on a double sided prototype rod
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/787491
work_keys_str_mv AT vallsjuan performanceofcmstobsilicondetectormodulesonadoublesidedprototyperod
AT povedaj performanceofcmstobsilicondetectormodulesonadoublesidedprototyperod