Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals
We present here the results of an analysis performed on the data of the M0' testbeam of the summer 2002. We find an estimate of the number of photoelectrons (pe) per MeV in pairs of APDs attached to PbWO4 crystals in the final configuration for CMS. The comparison between the light yields measu...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/787492 |
_version_ | 1780904430951989248 |
---|---|
author | Cavallari, F Franzoni, G Ghezzi, A Govoni, P Meregaglia, A Obertino, M |
author_facet | Cavallari, F Franzoni, G Ghezzi, A Govoni, P Meregaglia, A Obertino, M |
author_sort | Cavallari, F |
collection | CERN |
description | We present here the results of an analysis performed on the data of the M0' testbeam of the summer 2002. We find an estimate of the number of photoelectrons (pe) per MeV in pairs of APDs attached to PbWO4 crystals in the final configuration for CMS. The comparison between the light yields measured in laboratory and the ones at the testbeam shows an agreement within 4.5%. This result is of particular interest for the strategy of initial inter-calibration of the ECAL at CMS startup. |
id | cern-787492 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7874922019-09-30T06:29:59Zhttp://cds.cern.ch/record/787492engCavallari, FFranzoni, GGhezzi, AGovoni, PMeregaglia, AObertino, MRelative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystalsDetectors and Experimental TechniquesWe present here the results of an analysis performed on the data of the M0' testbeam of the summer 2002. We find an estimate of the number of photoelectrons (pe) per MeV in pairs of APDs attached to PbWO4 crystals in the final configuration for CMS. The comparison between the light yields measured in laboratory and the ones at the testbeam shows an agreement within 4.5%. This result is of particular interest for the strategy of initial inter-calibration of the ECAL at CMS startup.CMS-RN-2004-002oai:cds.cern.ch:7874922004-02-12 |
spellingShingle | Detectors and Experimental Techniques Cavallari, F Franzoni, G Ghezzi, A Govoni, P Meregaglia, A Obertino, M Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title | Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title_full | Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title_fullStr | Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title_full_unstemmed | Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title_short | Relative Light Yield comparison between laboratory and testbeam data for CMS ECAL PbWO4 crystals |
title_sort | relative light yield comparison between laboratory and testbeam data for cms ecal pbwo4 crystals |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/787492 |
work_keys_str_mv | AT cavallarif relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals AT franzonig relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals AT ghezzia relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals AT govonip relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals AT meregagliaa relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals AT obertinom relativelightyieldcomparisonbetweenlaboratoryandtestbeamdataforcmsecalpbwo4crystals |