Cargando…
Supersymmetric Particle Reconstruction with the CMS detector
TA method to reconstruct squark and gluino signals through the decay chain g~ -> q~qbar -> chi2 qqbar -> l~R l qqbar -> chi1 l+ l- qqbar is described. The sbottom is reconstructed exploiting the expected b-tagging performance of the CMS detector in the chain g~ ->...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/787496 |
_version_ | 1780904431825453056 |
---|---|
author | Chiorboli, M |
author_facet | Chiorboli, M |
author_sort | Chiorboli, M |
collection | CERN |
description | TA method to reconstruct squark and gluino signals through the decay chain g~ -> q~qbar -> chi2 qqbar -> l~R l qqbar -> chi1 l+ l- qqbar is described. The sbottom is reconstructed exploiting the expected b-tagging performance of the CMS detector in the chain g~ -> b~bbar -> chi2 bbbar -> l~R l bbbar -> chi1 l+ l- bbbar. The study is performed in three different mSUGRA scenarios. With favourable parameters, the mass peaks can be reconstructed with 10 fb-1 of integrated luminosity. The main source of error on the measurements of the signal masses arises from the chi1 mass uncertainty. |
id | cern-787496 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7874962019-09-30T06:29:59Zhttp://cds.cern.ch/record/787496engChiorboli, MSupersymmetric Particle Reconstruction with the CMS detectorDetectors and Experimental TechniquesTA method to reconstruct squark and gluino signals through the decay chain g~ -> q~qbar -> chi2 qqbar -> l~R l qqbar -> chi1 l+ l- qqbar is described. The sbottom is reconstructed exploiting the expected b-tagging performance of the CMS detector in the chain g~ -> b~bbar -> chi2 bbbar -> l~R l bbbar -> chi1 l+ l- bbbar. The study is performed in three different mSUGRA scenarios. With favourable parameters, the mass peaks can be reconstructed with 10 fb-1 of integrated luminosity. The main source of error on the measurements of the signal masses arises from the chi1 mass uncertainty.CMS-CR-2004-003oai:cds.cern.ch:7874962004-02-13 |
spellingShingle | Detectors and Experimental Techniques Chiorboli, M Supersymmetric Particle Reconstruction with the CMS detector |
title | Supersymmetric Particle Reconstruction with the CMS detector |
title_full | Supersymmetric Particle Reconstruction with the CMS detector |
title_fullStr | Supersymmetric Particle Reconstruction with the CMS detector |
title_full_unstemmed | Supersymmetric Particle Reconstruction with the CMS detector |
title_short | Supersymmetric Particle Reconstruction with the CMS detector |
title_sort | supersymmetric particle reconstruction with the cms detector |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/787496 |
work_keys_str_mv | AT chiorbolim supersymmetricparticlereconstructionwiththecmsdetector |