Cargando…

Development of a Beam Loss Detection System for the CLIC Test Facility 3

The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to tim...

Descripción completa

Detalles Bibliográficos
Autores principales: Lefèvre, T, Velasco, M, Wood, M, Braun, Hans Heinrich, Corsini, R, Gasior, M, Tecker, F A
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:https://dx.doi.org/10.1063/1.1831142
http://cds.cern.ch/record/787761
_version_ 1780904439393026048
author Lefèvre, T
Velasco, M
Wood, M
Braun, Hans Heinrich
Corsini, R
Gasior, M
Tecker, F A
author_facet Lefèvre, T
Velasco, M
Wood, M
Braun, Hans Heinrich
Corsini, R
Gasior, M
Tecker, F A
author_sort Lefèvre, T
collection CERN
description The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transients effectively, the beam loss monitor (BLM) technology must have a time response faster than a few nanoseconds. Preliminary tests have been performed in 2003 on the already existing part of the accelerator with the aim of studying the requirements for the system to be built in the future. The experimental data are compared to the results of Geant3 simulations. Based on these results, a complete beam loss detection system is currently designed for the observation of the beam transient loss and its minimization.
id cern-787761
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7877612020-08-28T08:05:21Zdoi:10.1063/1.1831142http://cds.cern.ch/record/787761engLefèvre, TVelasco, MWood, MBraun, Hans HeinrichCorsini, RGasior, MTecker, F ADevelopment of a Beam Loss Detection System for the CLIC Test Facility 3Accelerators and Storage RingsThe CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transients effectively, the beam loss monitor (BLM) technology must have a time response faster than a few nanoseconds. Preliminary tests have been performed in 2003 on the already existing part of the accelerator with the aim of studying the requirements for the system to be built in the future. The experimental data are compared to the results of Geant3 simulations. Based on these results, a complete beam loss detection system is currently designed for the observation of the beam transient loss and its minimization.AB-Note-2004-057CERN-AB-Note-2004-057oai:cds.cern.ch:7877612004-08-10
spellingShingle Accelerators and Storage Rings
Lefèvre, T
Velasco, M
Wood, M
Braun, Hans Heinrich
Corsini, R
Gasior, M
Tecker, F A
Development of a Beam Loss Detection System for the CLIC Test Facility 3
title Development of a Beam Loss Detection System for the CLIC Test Facility 3
title_full Development of a Beam Loss Detection System for the CLIC Test Facility 3
title_fullStr Development of a Beam Loss Detection System for the CLIC Test Facility 3
title_full_unstemmed Development of a Beam Loss Detection System for the CLIC Test Facility 3
title_short Development of a Beam Loss Detection System for the CLIC Test Facility 3
title_sort development of a beam loss detection system for the clic test facility 3
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1063/1.1831142
http://cds.cern.ch/record/787761
work_keys_str_mv AT lefevret developmentofabeamlossdetectionsystemfortheclictestfacility3
AT velascom developmentofabeamlossdetectionsystemfortheclictestfacility3
AT woodm developmentofabeamlossdetectionsystemfortheclictestfacility3
AT braunhansheinrich developmentofabeamlossdetectionsystemfortheclictestfacility3
AT corsinir developmentofabeamlossdetectionsystemfortheclictestfacility3
AT gasiorm developmentofabeamlossdetectionsystemfortheclictestfacility3
AT teckerfa developmentofabeamlossdetectionsystemfortheclictestfacility3