Cargando…
Development of a Beam Loss Detection System for the CLIC Test Facility 3
The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to tim...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1063/1.1831142 http://cds.cern.ch/record/787761 |
_version_ | 1780904439393026048 |
---|---|
author | Lefèvre, T Velasco, M Wood, M Braun, Hans Heinrich Corsini, R Gasior, M Tecker, F A |
author_facet | Lefèvre, T Velasco, M Wood, M Braun, Hans Heinrich Corsini, R Gasior, M Tecker, F A |
author_sort | Lefèvre, T |
collection | CERN |
description | The CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transients effectively, the beam loss monitor (BLM) technology must have a time response faster than a few nanoseconds. Preliminary tests have been performed in 2003 on the already existing part of the accelerator with the aim of studying the requirements for the system to be built in the future. The experimental data are compared to the results of Geant3 simulations. Based on these results, a complete beam loss detection system is currently designed for the observation of the beam transient loss and its minimization. |
id | cern-787761 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7877612020-08-28T08:05:21Zdoi:10.1063/1.1831142http://cds.cern.ch/record/787761engLefèvre, TVelasco, MWood, MBraun, Hans HeinrichCorsini, RGasior, MTecker, F ADevelopment of a Beam Loss Detection System for the CLIC Test Facility 3Accelerators and Storage RingsThe CLIC test facility 3 (CTF3) provides a 3.5A, 1.6us electron beam pulse of 150MeV at the end of the linac. The average beam power is 4 kW. Beam losses will be monitored all along the linac in order to keep the radiation level as low as possible. The heavy beam loading of the linac can lead to time transients of beam position, size and energy along the pulse. To compensate for these transients effectively, the beam loss monitor (BLM) technology must have a time response faster than a few nanoseconds. Preliminary tests have been performed in 2003 on the already existing part of the accelerator with the aim of studying the requirements for the system to be built in the future. The experimental data are compared to the results of Geant3 simulations. Based on these results, a complete beam loss detection system is currently designed for the observation of the beam transient loss and its minimization.AB-Note-2004-057CERN-AB-Note-2004-057oai:cds.cern.ch:7877612004-08-10 |
spellingShingle | Accelerators and Storage Rings Lefèvre, T Velasco, M Wood, M Braun, Hans Heinrich Corsini, R Gasior, M Tecker, F A Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title | Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title_full | Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title_fullStr | Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title_full_unstemmed | Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title_short | Development of a Beam Loss Detection System for the CLIC Test Facility 3 |
title_sort | development of a beam loss detection system for the clic test facility 3 |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1063/1.1831142 http://cds.cern.ch/record/787761 |
work_keys_str_mv | AT lefevret developmentofabeamlossdetectionsystemfortheclictestfacility3 AT velascom developmentofabeamlossdetectionsystemfortheclictestfacility3 AT woodm developmentofabeamlossdetectionsystemfortheclictestfacility3 AT braunhansheinrich developmentofabeamlossdetectionsystemfortheclictestfacility3 AT corsinir developmentofabeamlossdetectionsystemfortheclictestfacility3 AT gasiorm developmentofabeamlossdetectionsystemfortheclictestfacility3 AT teckerfa developmentofabeamlossdetectionsystemfortheclictestfacility3 |