Cargando…
MDT Autocalibration using MINUIT
A novel method for obtaining the space-drift time relationship r(t) of the ATLAS muon spectrometer monitored drift tubes (MDTs) from measured drift times, the so-called autocalibration procedure, is presented. Unlike existing methods, it is mathematically well-funded and makes use of the standard mi...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/788777 |
_version_ | 1780904475032027136 |
---|---|
author | Amelung, C |
author_facet | Amelung, C |
author_sort | Amelung, C |
collection | CERN |
description | A novel method for obtaining the space-drift time relationship r(t) of the ATLAS muon spectrometer monitored drift tubes (MDTs) from measured drift times, the so-called autocalibration procedure, is presented. Unlike existing methods, it is mathematically well-funded and makes use of the standard minimization tool MINUIT. Its performance is superior to that of the existing methods, which is demonstrated both with a toy simulation and with real data collected in the X5 test beam line in 2003. |
id | cern-788777 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7887772019-09-30T06:29:59Zhttp://cds.cern.ch/record/788777engAmelung, CMDT Autocalibration using MINUITDetectors and Experimental TechniquesA novel method for obtaining the space-drift time relationship r(t) of the ATLAS muon spectrometer monitored drift tubes (MDTs) from measured drift times, the so-called autocalibration procedure, is presented. Unlike existing methods, it is mathematically well-funded and makes use of the standard minimization tool MINUIT. Its performance is superior to that of the existing methods, which is demonstrated both with a toy simulation and with real data collected in the X5 test beam line in 2003.ATL-MUON-2004-020oai:cds.cern.ch:7887772004-08-17 |
spellingShingle | Detectors and Experimental Techniques Amelung, C MDT Autocalibration using MINUIT |
title | MDT Autocalibration using MINUIT |
title_full | MDT Autocalibration using MINUIT |
title_fullStr | MDT Autocalibration using MINUIT |
title_full_unstemmed | MDT Autocalibration using MINUIT |
title_short | MDT Autocalibration using MINUIT |
title_sort | mdt autocalibration using minuit |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/788777 |
work_keys_str_mv | AT amelungc mdtautocalibrationusingminuit |