Cargando…
Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS
For the physics program of the CMS experiment at the LHC to be carried out successfully, excellent electromagnetic calorimetry is required. Given the thermal properties of CMS ECAL, keeping the constant term of the energy resolution below 0.5% needs its temperature to be stabilized at 18 degrees C w...
Autores principales: | , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/790579 |
_version_ | 1780904522653106176 |
---|---|
author | Franzoni, F Baillon, P Cogan, J Ferri, F Ghezzi, A Govoni, P Negri, P Paganoni, M Pastrone, N Pullia, A Ragazzi, S Redaelli, N Rovelli, C Salerno, R Tabarelli de Fatis, T Teller, O |
author_facet | Franzoni, F Baillon, P Cogan, J Ferri, F Ghezzi, A Govoni, P Negri, P Paganoni, M Pastrone, N Pullia, A Ragazzi, S Redaelli, N Rovelli, C Salerno, R Tabarelli de Fatis, T Teller, O |
author_sort | Franzoni, F |
collection | CERN |
description | For the physics program of the CMS experiment at the LHC to be carried out successfully, excellent electromagnetic calorimetry is required. Given the thermal properties of CMS ECAL, keeping the constant term of the energy resolution below 0.5% needs its temperature to be stabilized at 18 degrees C within 0.05 degrees C. A prototype module of ECAL with the final cooling system has been tested at CERN to check its integration with the read-out electronics and verify that it complies with the severe thermal requirements.The thermal performance of the cooling system is reported here. |
id | cern-790579 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-7905792019-09-30T06:29:59Zhttp://cds.cern.ch/record/790579engFranzoni, FBaillon, PCogan, JFerri, FGhezzi, AGovoni, PNegri, PPaganoni, MPastrone, NPullia, ARagazzi, SRedaelli, NRovelli, CSalerno, RTabarelli de Fatis, TTeller, ODesign and Performance of the Cooling System for the Electromagnetic Calorimeter of CMSDetectors and Experimental TechniquesFor the physics program of the CMS experiment at the LHC to be carried out successfully, excellent electromagnetic calorimetry is required. Given the thermal properties of CMS ECAL, keeping the constant term of the energy resolution below 0.5% needs its temperature to be stabilized at 18 degrees C within 0.05 degrees C. A prototype module of ECAL with the final cooling system has been tested at CERN to check its integration with the read-out electronics and verify that it complies with the severe thermal requirements.The thermal performance of the cooling system is reported here.CMS-CR-2004-030oai:cds.cern.ch:7905792004-08-20 |
spellingShingle | Detectors and Experimental Techniques Franzoni, F Baillon, P Cogan, J Ferri, F Ghezzi, A Govoni, P Negri, P Paganoni, M Pastrone, N Pullia, A Ragazzi, S Redaelli, N Rovelli, C Salerno, R Tabarelli de Fatis, T Teller, O Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title | Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title_full | Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title_fullStr | Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title_full_unstemmed | Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title_short | Design and Performance of the Cooling System for the Electromagnetic Calorimeter of CMS |
title_sort | design and performance of the cooling system for the electromagnetic calorimeter of cms |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/790579 |
work_keys_str_mv | AT franzonif designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT baillonp designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT coganj designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT ferrif designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT ghezzia designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT govonip designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT negrip designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT paganonim designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT pastronen designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT pulliaa designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT ragazzis designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT redaellin designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT rovellic designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT salernor designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT tabarellidefatist designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms AT tellero designandperformanceofthecoolingsystemfortheelectromagneticcalorimeterofcms |