Cargando…

Beam Loss Monitoring on the CLIC Test Facility 3

With its 4kW average beam power, the CLIC test facility 3 (CTF3) is a machine where the control of beam losses is an important issue. Beam losses must be monitored all along the linac in order to keep the radiation level and the activation as low as possible. The Beam Loss Monitor (BLM) system curre...

Descripción completa

Detalles Bibliográficos
Autores principales: Lefèvre, T, Braun, H, Corsini, R, Gasior, M, Velasco, M, Wood, M
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/793456
_version_ 1780904586465247232
author Lefèvre, T
Braun, H
Corsini, R
Gasior, M
Velasco, M
Wood, M
author_facet Lefèvre, T
Braun, H
Corsini, R
Gasior, M
Velasco, M
Wood, M
author_sort Lefèvre, T
collection CERN
description With its 4kW average beam power, the CLIC test facility 3 (CTF3) is a machine where the control of beam losses is an important issue. Beam losses must be monitored all along the linac in order to keep the radiation level and the activation as low as possible. The Beam Loss Monitor (BLM) system currently under development is described. The goal of our effort is to provide quantitative beam loss measurements. An intensive simulation work has been carried out in order to estimate the e+ - e- showers in a realistic accelerator environment. Based on these results, we investigate two scenarios to measure beam losses using a set of 48 detectors distributed along the machine.
id cern-793456
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7934562023-07-20T15:03:53Zhttp://cds.cern.ch/record/793456engLefèvre, TBraun, HCorsini, RGasior, MVelasco, MWood, MBeam Loss Monitoring on the CLIC Test Facility 3Accelerators and Storage RingsWith its 4kW average beam power, the CLIC test facility 3 (CTF3) is a machine where the control of beam losses is an important issue. Beam losses must be monitored all along the linac in order to keep the radiation level and the activation as low as possible. The Beam Loss Monitor (BLM) system currently under development is described. The goal of our effort is to provide quantitative beam loss measurements. An intensive simulation work has been carried out in order to estimate the e+ - e- showers in a realistic accelerator environment. Based on these results, we investigate two scenarios to measure beam losses using a set of 48 detectors distributed along the machine.CERN-AB-2004-092CLIC-Note-611oai:cds.cern.ch:7934562004-08-17
spellingShingle Accelerators and Storage Rings
Lefèvre, T
Braun, H
Corsini, R
Gasior, M
Velasco, M
Wood, M
Beam Loss Monitoring on the CLIC Test Facility 3
title Beam Loss Monitoring on the CLIC Test Facility 3
title_full Beam Loss Monitoring on the CLIC Test Facility 3
title_fullStr Beam Loss Monitoring on the CLIC Test Facility 3
title_full_unstemmed Beam Loss Monitoring on the CLIC Test Facility 3
title_short Beam Loss Monitoring on the CLIC Test Facility 3
title_sort beam loss monitoring on the clic test facility 3
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/793456
work_keys_str_mv AT lefevret beamlossmonitoringontheclictestfacility3
AT braunh beamlossmonitoringontheclictestfacility3
AT corsinir beamlossmonitoringontheclictestfacility3
AT gasiorm beamlossmonitoringontheclictestfacility3
AT velascom beamlossmonitoringontheclictestfacility3
AT woodm beamlossmonitoringontheclictestfacility3