Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter

Approximately 2000 PMTs will be used to detect the Cherenkov light generated in the fibers embedded in the CMS-HF Forward Calorimeter. Hamamatsu R7525HA PMT was chosen for this purpose. We measured the transit time, transit time spread, pulse width, rise time, anode dark current, relative gain, and...

Descripción completa

Detalles Bibliográficos
Autores principales: Akgun, Ugur, Ayan, Ahmet Sedat, Brücken, P, Duru, Firdevs, Gülmez, Erhan, Mestvirishvili, Alexi, Miller, Michael, Olson, Jonathan, Önel, Y M, Schmidt, Ianos
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/796577
_version_ 1780904672444284928
author Akgun, Ugur
Ayan, Ahmet Sedat
Brücken, P
Duru, Firdevs
Gülmez, Erhan
Mestvirishvili, Alexi
Miller, Michael
Olson, Jonathan
Önel, Y M
Schmidt, Ianos
author_facet Akgun, Ugur
Ayan, Ahmet Sedat
Brücken, P
Duru, Firdevs
Gülmez, Erhan
Mestvirishvili, Alexi
Miller, Michael
Olson, Jonathan
Önel, Y M
Schmidt, Ianos
author_sort Akgun, Ugur
collection CERN
description Approximately 2000 PMTs will be used to detect the Cherenkov light generated in the fibers embedded in the CMS-HF Forward Calorimeter. Hamamatsu R7525HA PMT was chosen for this purpose. We measured the transit time, transit time spread, pulse width, rise time, anode dark current, relative gain, and single pulse linearity for each tube in the test station at the University of Iowa. Life-time, gain versus high voltage, and single photoelectron spectrum measurements were also done on a small sample of PMTs. All the tubes were tested to verify that they conform to the HF requirements.
id cern-796577
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7965772019-09-30T06:29:59Zhttp://cds.cern.ch/record/796577engAkgun, UgurAyan, Ahmet SedatBrücken, PDuru, FirdevsGülmez, ErhanMestvirishvili, AlexiMiller, MichaelOlson, JonathanÖnel, Y MSchmidt, IanosComplete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward CalorimeterDetectors and Experimental TechniquesApproximately 2000 PMTs will be used to detect the Cherenkov light generated in the fibers embedded in the CMS-HF Forward Calorimeter. Hamamatsu R7525HA PMT was chosen for this purpose. We measured the transit time, transit time spread, pulse width, rise time, anode dark current, relative gain, and single pulse linearity for each tube in the test station at the University of Iowa. Life-time, gain versus high voltage, and single photoelectron spectrum measurements were also done on a small sample of PMTs. All the tubes were tested to verify that they conform to the HF requirements.CMS-NOTE-2004-019oai:cds.cern.ch:7965772004-09-22
spellingShingle Detectors and Experimental Techniques
Akgun, Ugur
Ayan, Ahmet Sedat
Brücken, P
Duru, Firdevs
Gülmez, Erhan
Mestvirishvili, Alexi
Miller, Michael
Olson, Jonathan
Önel, Y M
Schmidt, Ianos
Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title_full Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title_fullStr Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title_full_unstemmed Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title_short Complete tests of 2000 Hamamatsu R7525HA Phototubes for the CMS-HF Forward Calorimeter
title_sort complete tests of 2000 hamamatsu r7525ha phototubes for the cms-hf forward calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/796577
work_keys_str_mv AT akgunugur completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT ayanahmetsedat completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT bruckenp completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT durufirdevs completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT gulmezerhan completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT mestvirishvilialexi completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT millermichael completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT olsonjonathan completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT onelym completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter
AT schmidtianos completetestsof2000hamamatsur7525haphototubesforthecmshfforwardcalorimeter