Response of RadFET Dosimeters to High Fluences of Fast Neutrons

We present irradiation experiments carried out on RadFETs in the 20.4 MeV high intensity T2 neutron beam at the CRC-UCL in Belgium. The aim of the test was to characterize the neutron response of RadFETs in view of their use as an integrated part of a radiationmonitoring sensor for the CERN Large Ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Ravotti, F, Glaser, M, Moll, Michael, Ilgner, C, Camanzi, B, Holmes-Siedle, A G
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2005.852709
http://cds.cern.ch/record/798311
_version_ 1780904706237792256
author Ravotti, F
Glaser, M
Moll, Michael
Ilgner, C
Camanzi, B
Holmes-Siedle, A G
author_facet Ravotti, F
Glaser, M
Moll, Michael
Ilgner, C
Camanzi, B
Holmes-Siedle, A G
author_sort Ravotti, F
collection CERN
description We present irradiation experiments carried out on RadFETs in the 20.4 MeV high intensity T2 neutron beam at the CRC-UCL in Belgium. The aim of the test was to characterize the neutron response of RadFETs in view of their use as an integrated part of a radiationmonitoring sensor for the CERN Large Hadron Collider (LHC) experiments. Two types of RadFETs were investigated up to a total neutron fluence of 3x10^14 cm-2 corresponding to a deposited dose of 744 Gy in Silicon. The responses of bare devices to neutrons are compared to the commonly used reference measurements with gamma rays. It is found that the gamma ray calibration cannot directly be adopted to convert the RadFET signals into neutron dose. In a second experiment, the influence of a plastic packaging, simulated by Polyethylene slabs of different thicknesses, was tested in the neutron beam and compared to GEANT4 Monte Carlo simulations. An increase of the RadFET neutron sensitivity by a factor of up to 7 due to the packaging is found. The influence of these findings on the conception of the radiationmonitoring sensor is discussed.
id cern-798311
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-7983112019-09-30T06:29:59Zdoi:10.1109/TNS.2005.852709http://cds.cern.ch/record/798311engRavotti, FGlaser, MMoll, MichaelIlgner, CCamanzi, BHolmes-Siedle, A GResponse of RadFET Dosimeters to High Fluences of Fast NeutronsHealth Physics and Radiation EffectsDetectors and Experimental TechniquesWe present irradiation experiments carried out on RadFETs in the 20.4 MeV high intensity T2 neutron beam at the CRC-UCL in Belgium. The aim of the test was to characterize the neutron response of RadFETs in view of their use as an integrated part of a radiationmonitoring sensor for the CERN Large Hadron Collider (LHC) experiments. Two types of RadFETs were investigated up to a total neutron fluence of 3x10^14 cm-2 corresponding to a deposited dose of 744 Gy in Silicon. The responses of bare devices to neutrons are compared to the commonly used reference measurements with gamma rays. It is found that the gamma ray calibration cannot directly be adopted to convert the RadFET signals into neutron dose. In a second experiment, the influence of a plastic packaging, simulated by Polyethylene slabs of different thicknesses, was tested in the neutron beam and compared to GEANT4 Monte Carlo simulations. An increase of the RadFET neutron sensitivity by a factor of up to 7 due to the packaging is found. The influence of these findings on the conception of the radiationmonitoring sensor is discussed.CERN-PH-EP-2004-045oai:cds.cern.ch:7983112004-08-31
spellingShingle Health Physics and Radiation Effects
Detectors and Experimental Techniques
Ravotti, F
Glaser, M
Moll, Michael
Ilgner, C
Camanzi, B
Holmes-Siedle, A G
Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title_full Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title_fullStr Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title_full_unstemmed Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title_short Response of RadFET Dosimeters to High Fluences of Fast Neutrons
title_sort response of radfet dosimeters to high fluences of fast neutrons
topic Health Physics and Radiation Effects
Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2005.852709
http://cds.cern.ch/record/798311
work_keys_str_mv AT ravottif responseofradfetdosimeterstohighfluencesoffastneutrons
AT glaserm responseofradfetdosimeterstohighfluencesoffastneutrons
AT mollmichael responseofradfetdosimeterstohighfluencesoffastneutrons
AT ilgnerc responseofradfetdosimeterstohighfluencesoffastneutrons
AT camanzib responseofradfetdosimeterstohighfluencesoffastneutrons
AT holmessiedleag responseofradfetdosimeterstohighfluencesoffastneutrons