Cargando…

The ALICE HMPID on-detector front-end and readout electronics

In the ALICE HMPID detector, Cherenkov photons are localised by measuring the charge induction on a MWPC cathode segmented into pads. Two ASICs have been developed: the Gassiplex07-3, which is an analogue 16-channels multiplexed front-end circuit dedicated to the readout of gaseous detector and the...

Descripción completa

Detalles Bibliográficos
Autor principal: Santiard, Jean-Claude
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2003.11.068
http://cds.cern.ch/record/802343
_version_ 1780904768936345600
author Santiard, Jean-Claude
author_facet Santiard, Jean-Claude
author_sort Santiard, Jean-Claude
collection CERN
description In the ALICE HMPID detector, Cherenkov photons are localised by measuring the charge induction on a MWPC cathode segmented into pads. Two ASICs have been developed: the Gassiplex07-3, which is an analogue 16-channels multiplexed front-end circuit dedicated to the readout of gaseous detector and the Dilogic-3, a sparse data scan digital processor. The combination of multiplexed and parallel- pipelined architecture allows to store several events between two L2 trigger and to transfer the 32-bits data words at a rate of 80 Mbytes per second through an optical data link.
id cern-802343
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8023432019-09-30T06:29:59Zdoi:10.1016/j.nima.2003.11.068http://cds.cern.ch/record/802343engSantiard, Jean-ClaudeThe ALICE HMPID on-detector front-end and readout electronicsDetectors and Experimental TechniquesIn the ALICE HMPID detector, Cherenkov photons are localised by measuring the charge induction on a MWPC cathode segmented into pads. Two ASICs have been developed: the Gassiplex07-3, which is an analogue 16-channels multiplexed front-end circuit dedicated to the readout of gaseous detector and the Dilogic-3, a sparse data scan digital processor. The combination of multiplexed and parallel- pipelined architecture allows to store several events between two L2 trigger and to transfer the 32-bits data words at a rate of 80 Mbytes per second through an optical data link.oai:cds.cern.ch:8023432004
spellingShingle Detectors and Experimental Techniques
Santiard, Jean-Claude
The ALICE HMPID on-detector front-end and readout electronics
title The ALICE HMPID on-detector front-end and readout electronics
title_full The ALICE HMPID on-detector front-end and readout electronics
title_fullStr The ALICE HMPID on-detector front-end and readout electronics
title_full_unstemmed The ALICE HMPID on-detector front-end and readout electronics
title_short The ALICE HMPID on-detector front-end and readout electronics
title_sort alice hmpid on-detector front-end and readout electronics
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2003.11.068
http://cds.cern.ch/record/802343
work_keys_str_mv AT santiardjeanclaude thealicehmpidondetectorfrontendandreadoutelectronics
AT santiardjeanclaude alicehmpidondetectorfrontendandreadoutelectronics