Cargando…

The Calibration Stategy of CMS Electromagnetic Calorimeter

Calibration is one of the main factors that set limits on the ultimate performance of the CMS electromagnetic calorimeter (ECAL) at LHC. Crystals raw intercalibration from laboratory measurements during assembly will be available for all the crystals and has been demonstrated to be a good precalibra...

Descripción completa

Detalles Bibliográficos
Autor principal: Meridiani, P
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/810667
_version_ 1780905294547648512
author Meridiani, P
author_facet Meridiani, P
author_sort Meridiani, P
collection CERN
description Calibration is one of the main factors that set limits on the ultimate performance of the CMS electromagnetic calorimeter (ECAL) at LHC. Crystals raw intercalibration from laboratory measurements during assembly will be available for all the crystals and has been demonstrated to be a good precalibration value at the start-up; some crystals will be also intercalibrated using an electron beam. In situ calibration with physics events will be the main tool to reduce the constant term of the emergy resolution to the design goal of 0.5%. In the following the calibration strategy will be described in detail.
id cern-810667
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8106672019-09-30T06:29:59Zhttp://cds.cern.ch/record/810667engMeridiani, PThe Calibration Stategy of CMS Electromagnetic CalorimeterDetectors and Experimental TechniquesCalibration is one of the main factors that set limits on the ultimate performance of the CMS electromagnetic calorimeter (ECAL) at LHC. Crystals raw intercalibration from laboratory measurements during assembly will be available for all the crystals and has been demonstrated to be a good precalibration value at the start-up; some crystals will be also intercalibrated using an electron beam. In situ calibration with physics events will be the main tool to reduce the constant term of the emergy resolution to the design goal of 0.5%. In the following the calibration strategy will be described in detail.CMS-CR-2004-045oai:cds.cern.ch:8106672004-10-01
spellingShingle Detectors and Experimental Techniques
Meridiani, P
The Calibration Stategy of CMS Electromagnetic Calorimeter
title The Calibration Stategy of CMS Electromagnetic Calorimeter
title_full The Calibration Stategy of CMS Electromagnetic Calorimeter
title_fullStr The Calibration Stategy of CMS Electromagnetic Calorimeter
title_full_unstemmed The Calibration Stategy of CMS Electromagnetic Calorimeter
title_short The Calibration Stategy of CMS Electromagnetic Calorimeter
title_sort calibration stategy of cms electromagnetic calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/810667
work_keys_str_mv AT meridianip thecalibrationstategyofcmselectromagneticcalorimeter
AT meridianip calibrationstategyofcmselectromagneticcalorimeter