Cargando…
Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam
The results of a comprehensive measurement program carried out at the CERN X7 test facility in June 2004 on a prototype ladder readout via a long Kapton interconnect are described. For a shaping time consistent with LHCb operational requirements the most probable value of the S/N ratio is found to b...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/811085 |
_version_ | 1780905304738758656 |
---|---|
author | Agari, M Bauer, M Blake, T Blouw, J Esperante-Pereira, D Gassner, J Köstner, S Lois, C Needham, M Perrin, A Pugatch, V Schmelling, M Vázquez, P Volyanskyy, D Voss, H |
author_facet | Agari, M Bauer, M Blake, T Blouw, J Esperante-Pereira, D Gassner, J Köstner, S Lois, C Needham, M Perrin, A Pugatch, V Schmelling, M Vázquez, P Volyanskyy, D Voss, H |
author_sort | Agari, M |
collection | CERN |
description | The results of a comprehensive measurement program carried out at the CERN X7 test facility in June 2004 on a prototype ladder readout via a long Kapton interconnect are described. For a shaping time consistent with LHCb operational requirements the most probable value of the S/N ratio is found to be 16 for particles that cross the detector close to the centre of a readout strip and 13 for particles that cross midway between two readout strips. These values are in excellent agreement with expectations. |
id | cern-811085 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8110852019-09-30T06:29:59Zhttp://cds.cern.ch/record/811085engAgari, MBauer, MBlake, TBlouw, JEsperante-Pereira, DGassner, JKöstner, SLois, CNeedham, MPerrin, APugatch, VSchmelling, MVázquez, PVolyanskyy, DVoss, HMeasurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beamDetectors and Experimental TechniquesThe results of a comprehensive measurement program carried out at the CERN X7 test facility in June 2004 on a prototype ladder readout via a long Kapton interconnect are described. For a shaping time consistent with LHCb operational requirements the most probable value of the S/N ratio is found to be 16 for particles that cross the detector close to the centre of a readout strip and 13 for particles that cross midway between two readout strips. These values are in excellent agreement with expectations.LHCb-2004-103CERN-LHCb-2004-103oai:cds.cern.ch:8110852004-12-21 |
spellingShingle | Detectors and Experimental Techniques Agari, M Bauer, M Blake, T Blouw, J Esperante-Pereira, D Gassner, J Köstner, S Lois, C Needham, M Perrin, A Pugatch, V Schmelling, M Vázquez, P Volyanskyy, D Voss, H Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title | Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title_full | Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title_fullStr | Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title_full_unstemmed | Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title_short | Measurements of a prototype ladder for the TT station in a 120~GeV/c $pi^-$ beam |
title_sort | measurements of a prototype ladder for the tt station in a 120~gev/c $pi^-$ beam |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/811085 |
work_keys_str_mv | AT agarim measurementsofaprototypeladderforthettstationina120gevcpibeam AT bauerm measurementsofaprototypeladderforthettstationina120gevcpibeam AT blaket measurementsofaprototypeladderforthettstationina120gevcpibeam AT blouwj measurementsofaprototypeladderforthettstationina120gevcpibeam AT esperantepereirad measurementsofaprototypeladderforthettstationina120gevcpibeam AT gassnerj measurementsofaprototypeladderforthettstationina120gevcpibeam AT kostners measurementsofaprototypeladderforthettstationina120gevcpibeam AT loisc measurementsofaprototypeladderforthettstationina120gevcpibeam AT needhamm measurementsofaprototypeladderforthettstationina120gevcpibeam AT perrina measurementsofaprototypeladderforthettstationina120gevcpibeam AT pugatchv measurementsofaprototypeladderforthettstationina120gevcpibeam AT schmellingm measurementsofaprototypeladderforthettstationina120gevcpibeam AT vazquezp measurementsofaprototypeladderforthettstationina120gevcpibeam AT volyanskyyd measurementsofaprototypeladderforthettstationina120gevcpibeam AT vossh measurementsofaprototypeladderforthettstationina120gevcpibeam |