Cargando…
High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
A safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout ti...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/816635 |
_version_ | 1780905417578119168 |
---|---|
author | Voronov, S A Voronov, Yu A Onishchenko, E M Simakov, A B Sosnovtsev, V V Suchkov, S Sugrobova, T A |
author_facet | Voronov, S A Voronov, Yu A Onishchenko, E M Simakov, A B Sosnovtsev, V V Suchkov, S Sugrobova, T A |
author_sort | Voronov, S A |
collection | CERN |
description | A safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout time of the fuse is 10-50 ms; whereupon the leakage current through it is less than 1 nA at a 2-kV voltage. The resistance of the fuse case is greater than or equivalent equal' greater than 10**1**2 Omega. Its overall dimensions are 5.8 multiplied by 3.8 multiplied by 2 mm. |
id | cern-816635 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8166352019-09-30T06:29:59Zhttp://cds.cern.ch/record/816635engVoronov, S AVoronov, Yu AOnishchenko, E MSimakov, A BSosnovtsev, V VSuchkov, SSugrobova, T AHigh-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experimentHealth Physics and Radiation EffectsA safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout time of the fuse is 10-50 ms; whereupon the leakage current through it is less than 1 nA at a 2-kV voltage. The resistance of the fuse case is greater than or equivalent equal' greater than 10**1**2 Omega. Its overall dimensions are 5.8 multiplied by 3.8 multiplied by 2 mm.oai:cds.cern.ch:8166352004 |
spellingShingle | Health Physics and Radiation Effects Voronov, S A Voronov, Yu A Onishchenko, E M Simakov, A B Sosnovtsev, V V Suchkov, S Sugrobova, T A High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title | High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title_full | High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title_fullStr | High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title_full_unstemmed | High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title_short | High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment |
title_sort | high-voltage safety fuses for the transition-radiation tracking detector in the atlas experiment |
topic | Health Physics and Radiation Effects |
url | http://cds.cern.ch/record/816635 |
work_keys_str_mv | AT voronovsa highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT voronovyua highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT onishchenkoem highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT simakovab highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT sosnovtsevvv highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT suchkovs highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment AT sugrobovata highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment |