High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment

A safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Voronov, S A, Voronov, Yu A, Onishchenko, E M, Simakov, A B, Sosnovtsev, V V, Suchkov, S, Sugrobova, T A
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/816635
_version_ 1780905417578119168
author Voronov, S A
Voronov, Yu A
Onishchenko, E M
Simakov, A B
Sosnovtsev, V V
Suchkov, S
Sugrobova, T A
author_facet Voronov, S A
Voronov, Yu A
Onishchenko, E M
Simakov, A B
Sosnovtsev, V V
Suchkov, S
Sugrobova, T A
author_sort Voronov, S A
collection CERN
description A safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout time of the fuse is 10-50 ms; whereupon the leakage current through it is less than 1 nA at a 2-kV voltage. The resistance of the fuse case is greater than or equivalent equal' greater than 10**1**2 Omega. Its overall dimensions are 5.8 multiplied by 3.8 multiplied by 2 mm.
id cern-816635
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8166352019-09-30T06:29:59Zhttp://cds.cern.ch/record/816635engVoronov, S AVoronov, Yu AOnishchenko, E MSimakov, A BSosnovtsev, V VSuchkov, SSugrobova, T AHigh-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experimentHealth Physics and Radiation EffectsA safety fuse has been designed for the electrical protection of gas- filled detectors in the ATLAS experiment at CERN (Geneva, Switzerland). The fuse is a polished lithium niobate plate with a titanium strip of 91-kOmega resistance deposited by the photolithographic technique. The forced blowout time of the fuse is 10-50 ms; whereupon the leakage current through it is less than 1 nA at a 2-kV voltage. The resistance of the fuse case is greater than or equivalent equal' greater than 10**1**2 Omega. Its overall dimensions are 5.8 multiplied by 3.8 multiplied by 2 mm.oai:cds.cern.ch:8166352004
spellingShingle Health Physics and Radiation Effects
Voronov, S A
Voronov, Yu A
Onishchenko, E M
Simakov, A B
Sosnovtsev, V V
Suchkov, S
Sugrobova, T A
High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title_full High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title_fullStr High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title_full_unstemmed High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title_short High-voltage safety fuses for the transition-radiation tracking detector in the ATLAS experiment
title_sort high-voltage safety fuses for the transition-radiation tracking detector in the atlas experiment
topic Health Physics and Radiation Effects
url http://cds.cern.ch/record/816635
work_keys_str_mv AT voronovsa highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT voronovyua highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT onishchenkoem highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT simakovab highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT sosnovtsevvv highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT suchkovs highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment
AT sugrobovata highvoltagesafetyfusesforthetransitionradiationtrackingdetectorintheatlasexperiment